Subject-specific finite element analysis of the human medial collateral ligament during valgus knee loading.
نویسندگان
چکیده
The objectives of this study were (1) to develop subject-specific experimental and finite element (FE) techniques to study the three-dimensional stress-strain behavior of ligaments, with application to the human medial collateral ligament (MCL), and (2) to determine the importance of subject-specific material properties and initial (in situ) strain distribution for prediction of the strain distribution in the MCL under valgus loading. Eight male knees were subjected to varus-valgus loading at flexion angles of 0 degrees, 30 degrees, and 60 degrees. Three-dimensional joint kinematics and MCL strains were recorded during kinematic testing. Following testing, the MCL of each knee was removed to allow measurement of the in situ strain distribution and to perform material testing. A FE model of the femur-MCL-tibia complex was constructed for each knee to simulate valgus loading at each flexion angle, using subject-specific bone and ligament geometry, material properties, and joint kinematics. A transversely isotropic hyperelastic material model was used to represent the MCL. The MCL in situ strain distribution at full extension was used to apply in situ strain to each MCL FE model. FE predicted MCL strains during valgus loading were compared to experimental measurements using regression analysis. The subject-specific FE predictions of strain correlated reasonably well with experimentally measured MCL strains (R(2)=0.83, 0.72, and 0.66 at 0 degrees, 30 degrees, and 60 degrees, respectively). Despite large inter-subject variation in MCL material properties, MCL strain distributions predicted by individual FE models that used average MCL material properties were strongly correlated with subject-specific FE strain predictions (R(2)=0.99 at all flexion angles). However, predictions by FE models that used average in situ strain distributions yielded relatively poor correlations with subject-specific FE predictions (R(2)=0.44, 0.35, and 0.33 at flexion angles of 0 degrees, 30 degrees, and 60 degrees, respectively). The strain distribution within the MCL was nonuniform and changed with flexion angle. The highest MCL strains occurred at full extension in the posterior region of the MCL proximal to the joint line during valgus loading, suggesting this region may be most vulnerable to injury under these loading conditions. This work demonstrates that subject-specific FE models can predict the complex, nonuniform strain fields that occur in ligaments due to external loading of the joint.
منابع مشابه
Medial collateral ligament insertion site and contact forces in the ACL-deficient knee.
The objectives of this research were to determine the effects of anterior cruciate ligament (ACL) deficiency on medial collateral ligament (MCL) insertion site and contact forces during anterior tibial loading and valgus loading using a combined experimental-finite element (FE) approach. Our hypothesis was that ACL deficiency would increase MCL insertion site forces at the attachments to the ti...
متن کاملSubject-specific Finite Element Models Can Predict Strain in the Human Medialcollateral Ligament under Valgus Loading
INTRODUCTION: Despite the many investigations of ligament function, the exact role of specific ligaments in maintaining joint stability, the cause and effect of injuries, and the efficacy of various reconstructive procedures remain unclear or unknown. This is partially due to inherent measurement limitations of experimental studies. The finite element (FE) method can predict spatial and tempora...
متن کاملFinite Element Modeling of Knee and Shoulder Ligaments
The medial collateral ligament (MCL) is the primary restraint to knee valgus rotation and a secondary restraint to anterior tibial translation. The anterior cruciate ligament (ACL) is a primary restraint to anterior tibial translation, but its contribution to valgus restraint was debated. To address this, a combined experimental and computational study was conducted to determine the effect of A...
متن کاملStrain in the human medial collateral ligament during valgus loading of the knee.
The medial collateral ligament is one of the most frequently injured ligaments in the knee. Although the medial collateral ligament is known to provide a primary restraint to valgus and external rotations, details regarding its precise mechanical function are unknown. In this study, strain in the medial collateral ligament of eight knees from male cadavers was measured during valgus loading. A ...
متن کاملComputational study on the effect of malalignment of the tibial component on the biomechanics of total knee arthroplasty
OBJECTIVES Malalignment of the tibial component could influence the long-term survival of a total knee arthroplasty (TKA). The object of this study was to investigate the biomechanical effect of varus and valgus malalignment on the tibial component under stance-phase gait cycle loading conditions. METHODS Validated finite element models for varus and valgus malalignment by 3° and 5° were deve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of orthopaedic research : official publication of the Orthopaedic Research Society
دوره 21 6 شماره
صفحات -
تاریخ انتشار 2003