An automated three-dimensional plus time registration framework for dynamic MR renography
نویسندگان
چکیده
Dynamic contrast-enhanced 3D images of the kidneys, or 3D MR renography, has the potential for broad clinical applications, but suffers from respiratory motion that limits analysis and interpretation. Manual registration is prohibitively labor-intensive. In this paper, a fully automated technique, Wavelet Representation and the Fourier Transform (WRFT) method, that corrects for translation and rotation motion in 3D MR renography is presented. The method was composed by anisotropic denoising, wavelet-based feature extraction, and Fourier-based registration. This was first evaluated on a set of simulated MR renography images with defined degrees of kidney motion. The method was then tested on 24 clinical patient MR renography data sets. Results of clinical testing were compared with the results obtained using a mutual information registration method. Based on intrarenal time-intensity curves, our method showed robust and consistent agreement with the results of manually coregistered data sets. 2009 Elsevier Inc. All rights reserved.
منابع مشابه
Semi-automated application for kidney motion correction and filtration analysis in MR renography
Introduction: Altered renal function commonly affects patients with cirrhosis, a consequence of chronic liver disease. From lowdose contrast material-enhanced magnetic resonance (MR) renography, we can estimate the Glomerular Filtration Rate (GFR), an important parameter to assess renal function. Two-dimensional MR images are acquired every 2 seconds for approximately 5 minutes during free brea...
متن کاملRegistration of Time-Series Contrast Enhanced Magnetic Resonance Images for Renography
Renovascular disease is an important cause of hypertension. For assessing treatment options for renovascular disease such as angioplasty or nephrectomy, it is important to characterize the renal tissue. Magnetic resonance (MR) renography is becoming a viable method for characterization of the renal tissue. However, analysis of MR renography is hampered by tissue motion. We investigate two autom...
متن کاملAn Iterative Framework for Registration and Segmentation of Dynamic Three-Dimensional MR Renography
Dynamic MR renography has broad clinical applications, but suffers from respiratory motion that limits analysis and interpretation. Since each examination yields at least 10-20 serial 3D images of the abdomen, manual registration is prohibitively labor-intensive [1]. An effective framework for registration and segmentation is necessary to analyze these data sets. Our purpose was to develop and ...
متن کاملAutomatic 4-D Registration in Dynamic MR Renography Based on Over-Complete Dyadic Wavelet and Fourier Transforms
Dynamic contrast-enhanced 4-D MR renography has the potential for broad clinical applications, but suffers from respiratory motion that limits analysis and interpretation. Since each examination yields at least over 10-20 serial 3-D images of the abdomen, manual registration is prohibitively labor-intensive. Besides in-plane motion and translation, out-of-plane motion and rotation are observed ...
متن کاملDynamic three-dimensional MR renography for the measurement of single kidney function: initial experience.
A three-dimensional magnetic resonance (MR) renographic method to measure single kidney glomerular filtration rate (GFR) and split renal function was developed that is based on renal signal intensity measurements during 2-3 minutes after intravenous injection of a low dose (2 mL or 0.01 mmol/kg) of gadopentetate dimeglumine. In nine subjects, single kidney MR GFR indices correlated well with te...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- J. Visual Communication and Image Representation
دوره 21 شماره
صفحات -
تاریخ انتشار 2010