Multi-laboratory comparison of three heparin-Mn2+ precipitation procedures for estimating cholesterol in high-density lipoprotein.

نویسندگان

  • J J Albers
  • G R Warnick
  • D Wiebe
  • P King
  • P Steiner
  • L Smith
  • C Breckenridge
  • A Chow
  • K Kuba
  • S Weidman
  • H Arnett
  • P Wood
  • A Shlagenhaft
چکیده

Plasma high-density lipoprotein is commonly estimated by measuring the cholesterol remaining in plasma supernatant solutions after other lipoproteins, which contain apolipoprotein B, are precipitated with heparin and Mn2+. The method (method I) now in use by the Lipid Research Clinics, in which Mn2+ is at 46 mmol/liter final concentration, is reasonably accurate, but precipitation and sedimentation of lipoproteins other than high-density lipoproteins is often incomplete. We evaluated two modifications of method I. In method II, the Mn2+ concentration was doubled; the second modification (method III) included the increased Mn2+ concentration in a combined heparin Mn2+ reagent, decreased sample volume (2 ml), and a shorter incubation time (10 min at room temperature). The percentages of samples with turbid supernates (i.e., incomplete sedimentation) by methods I, II, and III were 9, 3, and 2%, respectively. Among non-turbid supernates, the percentages of samples containing measurable apolipoprotein B (incomplete precipitation) were 79, 19, and 16%, respectively. We conclude that method III is the most convenient and accurate of the three procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparability of results by simplified methods for measuring serum lipoprotein cholesterol in a pediatric population.

We compared serum lipoprotein cholesterol concentrations in a randomly selected subsample (n = 406) population of children (ages 5 to 17 years), as measured by the heparin-Ca2+ and the heparin-Mn2+ precipitation methods. Statistical analysis showed significant differences between results by these methods, especially in values for VLDL- and HDL-cholesterol (mean difference: VLDL-cholesterol, -61...

متن کامل

High-density-lipoprotein cholesterol in heparin-MnCl2 supernates determined with the Dow enzymic method after precipitation of Mn2+ with HCO3-.

Manganese interferes with enzymic cholesterol methods. In this study, we enzymically measured high-density-lipoprotein (HDL) cholesterol in heparin-Mn2+ supernates that had been treated with NaHCO3 (91 mmol/L) to precipitate Mn2+, and compared results with those by an automated Liebermann- Burchard method. For untreated supernates of 96 fresh plasma samples, the enzymic values were 10.4% higher...

متن کامل

Applicability of various quality-control sera to assay of high-density lipoprotein cholesterol.

Effective internal quality control and external quality assessment of high-density lipoprotein cholesterol assay is made difficult by analyte instability, and the suitability of quality-control sera for this purpose has not been studied. We have therefore investigated the properties of 25 different control sera from 15 suppliers by estimating within-batch precision for the two precipitation pro...

متن کامل

EnzymeImmunoassayof Free Thyroxinin DriedBloodSampleson Filter

Centers forDiseaseControl, Atlanta, GA, 1982.(The manual may be obtained by writing Dr. Gerald R. Cooper, Center for Environmental Health, Centers for Disease Control,Atlanta, GA 30333.) 3. Hutt Y, Kior HU, WechslerJG, DitschuneitH. Three different methods for estimating high density lipoprotein cholesterol. Clin Chim Acta 128, 173-176 (1983). 4. Chicaud P, LambertD, Mejean L, eta!. Comparative...

متن کامل

Cholesterol determination in high-density lipoproteins separated by three different methods.

We describe a simplified method for measuring high-density lipoprotein cholesterol in serum after very-low- and low-density lipoproteins have been precipitated from the specimen with sodium phosphotungstate and Mg2+. Values so obtained correlate well with values obtained with the heparin-Mn2+ precipitation technique (r = 0.95, CV less than 5% in 66% of the subjects studied and between 5 and 10%...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 1978