Requires Biological Calibration Accuracy of Whole - Body Plethysmography
نویسندگان
چکیده
2009;135;1476-1480 Chest Klug, Birgitte Hanel and Hans Bisgaard Porntiva Poorisrisak, Carsten Vrang, Jorn Molgaard Henriksen, Bent Requires Biological Calibration Accuracy of Whole-Body Plethysmography http://chestjournal.chestpubs.org/content/135/6/1476.full.html services can be found online on the World Wide Web at: The online version of this article, along with updated information and ISSN:0012-3692 ) http://chestjournal.chestpubs.org/site/misc/reprints.xhtml ( written permission of the copyright holder. this article or PDF may be reproduced or distributed without the prior Dundee Road, Northbrook, IL 60062. All rights reserved. No part of Copyright2009by the American College of Chest Physicians, 3300 Physicians. It has been published monthly since 1935. is the official journal of the American College of Chest Chest
منابع مشابه
Measuring respiratory function in mice using unrestrained whole-body plethysmography.
Respiratory dysfunction is one of the leading causes of morbidity and mortality in the world and the rates of mortality continue to rise. Quantitative assessment of lung function in rodent models is an important tool in the development of future therapies. Commonly used techniques for assessing respiratory function including invasive plethysmography and forced oscillation. While these technique...
متن کاملRespiratory inductance plethysmography in healthy infants: a comparison of three calibration methods.
Respiratory inductance plethysmography (RIP) measures respiration from body surface movements. Various techniques have been proposed for calibration in order that RIP may be used quantitatively. These include calculation of the proportionality constant of ribcage to abdominal volume change (K). The aims of this study were to 1) establish whether a fixed value of K could be used for calibration,...
متن کاملRespiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration.
BACKGROUND Portable respiratory inductive plethysmography (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position. OBJECTIVES To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment of RIP calibration using position sensor f...
متن کاملEstablishing Calibration Models and Error Envelopes of a 3D Whole Body Scanning System
The accuracy is important for a 3D whole body scanning system. In order to analyze the measurement error, a set of dimension-certified measurement equipment whose true dimensions were certified was introduced. The calibration models of height, breadth and depth measurement between measured values and true dimensions were established respectively and relevant error envelopes were derived. A veri...
متن کاملEvaluation of air-displacement plethysmography in children aged 5-7 years using a three-component model of body composition.
The aim of the present study was to evaluate air-displacement plethysmography (ADP) in children aged 5-7 years. Body-composition measurements were obtained by ADP, (2)H dilution and anthropometry in twenty-eight children. Calculation of body volume by ADP was undertaken using adult and children's equations for predicting lung volume and surface area. Fat-free mass (FFM) was calculated using a t...
متن کامل