Effect of Deep Cryogenic Treatment on Cyclic Fatigue of Endodontic Rotary Nickel Titanium Instruments
نویسندگان
چکیده
INTRODUCTION Cyclic fatigue is the common reason for breakage of rotary instruments. This study was conducted to evaluate the effect of cryogenic treatment (CT) in improving the resistance to cyclic fatigue of endodontic rotary instruments. METHODS AND MATERIALS In this in vitro study, 20 RaCe and 20 Mtwo files were randomly divided into two groups of negative control and CT. CT files were stored in liquid nitrogen at -196°C for 24 h, and then were gradually warmed to the room temperature. All files were used (at torques and speeds recommended by their manufacturers) in a simulated canal with a 45° curvature until breakage. The time to fail (TF) was recorded and used to calculate the number of cycle to fail (NCF). Groups were compared using independent-samples t-test. RESULTS Mean NCFs were 1248.2±68.1, 1281.6±78.6, 4126.0±179.2, and 4175.4±190.1 cycles, for the Mtwo-control, Mtwo-CT, RaCe-control, and RaCe-CT, respectively. The difference between the controls and their respective CT groups were not significant (P>0.3). The difference between the systems was significant. CONCLUSION Deep CT did not improve resistance to cyclic fatigue of the evaluated rotary files.
منابع مشابه
Fracture resistance of electropolished rotary nickel-titanium endodontic instruments.
The purpose of this study was to investigate the effect of electropolishing on cyclic flexural fatigue and torsional strength of rotary nickel-titanium endodontic instruments. Electropolished and nonelectropolished ISO size 30 (0.04 taper) EndoWave (J Morita Corporation, Osaka, Japan), ProFile (Dentsply Maillefer, Ballaigues, Switzerland), and RaCe (FKG, La-Chaux De Fonds, Switzerland) instrume...
متن کاملEffect of cryogenic treatment on nickel-titanium endodontic instruments.
AIM To investigate the effects of cryogenic treatment on nickel-titanium endodontic instruments. The null hypothesis was that cryogenic treatment would result in no changes in composition, microhardness or cutting efficiency of nickel-titanium instruments. METHODOLOGY Microhardness was measured on 30 nickel-titanium K-files (ISO size 25) using a Vicker's indenter. Elemental composition was me...
متن کاملA dozen ways to prevent nickel-titanium rotary instrument fracture.
BACKGROUND and Overview. With the increased use of nickel-titanium (NiTi) rotary instruments for root canal preparation in endodontics, instrument fracture has become more prevalent. Extensive research has been conducted on the physical properties and mechanical characteristics of NiTi rotary instruments, as well as the factors that can contribute to instrument failure. NiTi rotary instruments ...
متن کاملTorsion Property and Cyclic Fatigue Fracture Behavior of Nickel-Titanium Endodontic Instruments
The torsion property and rotary fatigue fracture behavior of Smart K file and R reamer made of nickel titanium alloy have been studied by means of Shimadzu Autograph DDS-10T universal tester and man-made cyclic system with curved copper tubes as simulated root canal. The instrument surface and the cyclic fatigue fracture surface have been investigated by optical microscope and scanning electro...
متن کاملCyclic fatigue resistance and three-dimensional analysis of instruments from two nickel-titanium rotary systems.
AIM To determine how instrument design affects the fatigue life of two nickel-titanium (Ni-Ti) rotary systems (Mtwo and ProTaper) under cyclic fatigue stress in simulated root canals. METHODOLOGY Cyclic fatigue testing of instruments was performed in stainless steel artificial canals with radii of curvature of 2 or 5 mm and an angle of curvature of 60 degrees . A total of 260 instruments were...
متن کامل