Evaluation of X-ray doses and their corresponding biological effects on experimental animals in cone-beam micro-CT scans (R-mCT2)
نویسندگان
چکیده
Studies show that the radiation dose received during a micro-CT examination may have adverse effects on living subjects. However, the correlations between the biological effects and the radiation doses have never been thoroughly evaluated in the majority of cases. In this study, we evaluated the biological radiation effects of measured radiation doses in ICR mice using cone-beam micro-CT scans. Long-term in vivo whole-body micro-CT scans of ICR mice were performed for a duration of 4 weeks. Although a scanning frequency of three scans per week is higher than that necessary for conventional studies, this study represents particular cases where the subjects may undergo an extreme number of examinations. The average X-ray dose of a CT scan measures 16.19 mGy at the center of a phantom and 16.24 mGy at an offset position of 7.5 mm from the center of the phantom. The total average dose at the center of the phantom during the 4-week scanning period was 194.3 mGy. No significant radiation effects were observed in the weight gain curves, organ weights, blood analyses, litter sizes, reared offspring sizes, and the histopathologic results. Therefore, it is unlikely that the measured doses for the CT scans caused any radiation damage in the mice.
منابع مشابه
Assessment of compliance levels of effective doses in pediatric CT
Introduction: Computed tomography (CT) is a medical imaging modality that produces 3-D cross-sectional images of tissues using several X-ray projections at different angles. Since its introduction in the 1970s, CT usage has been on the increase for both adults and pediatrics. A major challenge of this modality is the high doses of radiation exposure to patients, especially in p...
متن کاملEvaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)
Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...
متن کاملCone-beam computed tomography images of phantoms with simulating trabecular bone structure fabricated using micro-stereolithography.
OBJECTIVE Phantoms with simulating mandibular trabecular bone structure fabricated using micro-stereolithography were applied for a quantitative evaluation of cone-beam computed tomography (CT) images. MATERIALS AND METHODS Phantoms with a three-dimensional lattice, in which a square pillar was set at 0.10, 0.20, 0.30 and 0.40 mm at the edge, spaced at 0.60 mm, were made of an acrylic resin u...
متن کاملAn in-vivo study on the energy dependence of X-ray biological effectiveness
Background: The International Commission on Radiological Protection (ICRP) has attributed the same relative risk for X and gamma radiations of all energies. Several studies have proven that the biological effect of low energy photon is more than that of higher ones. The assessment of risks is important due to the wide use of low energy X-rays for mammography screening and other diagnostic appli...
متن کاملGeometric Parameters Estimation and Calibration in Cone-Beam Micro-CT
The quality of Computed Tomography (CT) images crucially depends on the precise knowledge of the scanner geometry. Therefore, it is necessary to estimate and calibrate the misalignments before image acquisition. In this paper, a Two-Piece-Ball (TPB) phantom is used to estimate a set of parameters that describe the geometry of a cone-beam CT system. Only multiple projections of the TPB phantom a...
متن کامل