Hybrid Control of the Berkeley Lower Extremity Exoskeleton
نویسندگان
چکیده
The Berkeley Lower Extremity Exoskeleton is the first functional energetically autonomous load carrying human exoskeleton and was demonstrated at U.C. Berkeley, walking at the average speed of 0.9 m/s (2 mph) while carrying a 34 kg (75 lb) payload. The original published controller, called the BLEEX Sensitivity Amplification Controller, was based on positive feedback and was designed to increase the closed loop system sensitivity to its wearer’s forces and torques without any direct measurement from the wearer. This controller was successful at allowing natural and unobstructed load support for the pilot. This article presents an improved control scheme we call “hybrid” BLEEX control that adds robustness to changing BLEEX backpack payload. The walking gait cycle is divided into stance control and swing control phases. Position control is used for the BLEEX stance leg (including the torso and backpack) and a sensitivity amplification controller is used for the swing leg. The controller is also designed to smoothly transition between these two schemes as the pilot walks. With hybrid control, the controller does not require a good model of the BLEEX torso and payload, which is difficult to obtain and subject to change as payload is added and removed. As a tradeoff, the position control used in this method requires the human to wear seven inclinometers to measure human limb and torso angles. These additional sensors require careful design to securely fasten them to the human and increase the time to
منابع مشابه
The Berkeley Lower Extremity Exoskeleton Project
In October 2003, the first functional load-bearing and energetically autonomous exoskeleton was demonstrated at Berkeley, walking at the average speed of two miles per hour while carrying 75 pounds of load. DARPA funded the Berkeley Lower Extremity Exoskeleton (BLEEX) project in 2000 at Berkeley. In general, four fundamental technologies were tackled during the course of this project. These fou...
متن کاملEffect of Target Impedance Selection on the Lower Extremity Assistive Exoskeleton Performance
Exoskeletons are utilized extensively in robotic rehabilitation and power augmentation purposes. One of the most recognised control algorithms utilized in this field is the impedance controller. Impedance control approach provides the capability of realizing different rehabilitation exercises by tuning the target impedance gains. Trial and error experimental approach is one of the most common m...
متن کاملControl and system identification for the Berkeley lower extremity exoskeleton (BLEEX)
The Berkeley lower extremity exoskeleton (BLEEX) is an autonomous robotic device whose function is to increase the strength and endurance of a human pilot. In order to achieve an exoskeleton controller which reacts compliantly to external forces, an accurate model of the dynamics of the system is required. In this report, a series of system identification experiments was designed and carried ou...
متن کاملHybrid Control of the Berkeley Lower Extremity Exoskeleton (BLEEX)
The first functional load-carrying and energetically autonomous exoskeleton was demonstrated at U.C. Berkeley, walking at the average speed of 0.9 m/s (2 mph) while carrying a 34 kg (75 lb) payload. The original BLEEX sensitivity amplification controller, based on positive feedback, was designed to increase the closed loop system sensitivity to its wearer’s forces and torques without any direct...
متن کامل