Breath-hold gadolinium-enhanced three-dimensional MR thoracic aortography: higher spatial resolution imaging with phased-array coil and three-dimensional surface display.

نویسندگان

  • T Nakanishi
  • R Hata
  • A Tamura
  • M Kohata
  • K Miyasaka
  • T Kajima
  • H Fukuoka
  • K Ito
چکیده

The aim of this study was to examine signal intensities of data sets from MR thoracic aortography and to evaluate three-dimensional surface display (3DSD) for postprocessing. Twenty-five patients were imaged with gadolinium-enhanced 3D fast gradient echo sequence. The intensity at the aortic arch was significantly higher than that at the mediastinal fat (p<0.0001). The signal-to-noise ratio was lower at the aortic arch than at the ascending and descending aorta, whereas the contrast-to-noise ratio was fairly high at the aortic arch. Although in one case (4%) the intensity at the arch was smaller than that at the mediastinal fat, 3DSD was successfully performed in all cases. Superiority of 3DSD over maximum intensity projection was obtained in 67% of the cases. 3DSD was evaluated to be superior to maximum intensity projection in all cases of thoracic aortic aneurysm and coarctation of aorta. Higher resolution MR thoracic aortography could be successfully performed with phased-array coil and 3DSD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Cardiac-synchronized and Unsynchronized Gadolinium-enhanced Three-dimensional Magnetic Resonance Angiography of the Thoracic Aorta

Purpose: The purpose of this study was to compare multi-slab cardiac-synchronized breath-hold Gd-enhanced threedimensional MR angiography (1) with unsynchronized breath-hold three-dimensional MR angiography(Z-4) in patients for the evaluation of thoracic aortic disease. We hypothesized that the use of cardiac-synchronization should minimally provide the same diagnostic information and additiona...

متن کامل

Transesophageal Magnetic Resonance Imaging of Thoracic Aorta

Introduction Current standard techniques for imaging the thoracic aorta include CT, standard body-coil MRI, transesophageal echocardiography (TEE), and contrast aortography. Each of these techniques suffers some limitation in its ability to allow detailed mapping of the aortic wall and its anatomic and functional lesions. Body-coil MRI and CT lack adequate resolution of the aortic wall for prec...

متن کامل

A comparison of a T1 weighted 3D gradient-echo sequence with three different parallel imaging reduction factors, breath hold and free breathing, using a 32 channel coil at 1.5 T. A preliminary study.

PURPOSE To investigate whether increasing temporal resolution with higher parallel imaging (PI) reduction factors (RF) in both breath-hold and free breathing approaches, using a non-contrast T1-weighted 3D gradient echo (GRE) sequence and a 32-channel phased array coil, permits diagnostic image quality, with potential application in patients unable to cooperate with breath-hold requirements. ...

متن کامل

Myocardial perfusion and MR angiography of chest with SH U 555 C: results of placebo-controlled clinical phase i study.

PURPOSE To evaluate SH U 555 C for contrast material-enhanced three-dimensional magnetic resonance (MR) angiography of the chest and myocardial perfusion. MATERIALS AND METHODS For chest MR angiography, SH U 555 C was intravenously injected at four doses (5, 10, 20, and 40 micromol iron [Fe] per kilogram of body weight) into three healthy volunteers per dose group, and placebo (saline) was in...

متن کامل

Feasibility of integrating high-spatial-resolution 3D breath-hold coronary MR angiography with myocardial perfusion and viability examinations.

The study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. All subjects provided informed consent. Three-dimensional breath-hold coronary magnetic resonance (MR) angiography with use of steady-state free precession was performed in 12 patients up to 20 minutes after 0.2 mmol gadolinium-based contrast material per kilogram of body weight ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hiroshima journal of medical sciences

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2000