Mid-term outcome of a modular, cementless, proximally hydroxyapatite-coated, anatomic femoral stem.

نویسندگان

  • David J Cossetto
  • Anil Goudar
چکیده

PURPOSE To report the mid-term outcome of a modular, cementless, proximally hydroxyapatitecoated, anatomic femoral stem in total hip arthroplasty (THA). METHODS 160 consecutive patients aged 42 to 92 (mean, 70) years underwent 185 cementless THAs for primary osteoarthritis or femoral neck fractures. All procedures were performed by a single surgeon using the same modular, cementless, proximally hydroxyapatite-coated, anatomic femoral stem, regardless of age and bone quality. Clinical evaluation (pain, range of movement, and ability to walk) was based on the Merle d'Aubigne and Postel scores. Radiological assessment was based on criteria by Engh et al. in the 7 Gruen zones with regard to the presence of radiolucent lines, osteolysis, cancellous condensation, cortical hypertrophy or atrophy, reactive lines, and pedestal formation. Failure of the stem was defined as revision or impending revision because of aseptic loosening or pain. RESULTS Of the 160 patients, 21 died and none were lost to follow-up. In 3 of the 21 patients, the femoral stems were revised for periprosthetic fractures after a fall at 6 weeks, 10 months, and 3.8 years. 138 patients (162 THAs) completed a mean follow-up of 7.8 (range, 5.5-10.4) years. Their overall mean Merle d'Aubigne and Postel scores increased from 7.09 preoperatively to 16.36 postoperatively. The mean Engh score was 24.9 out of 27, with the mean score for femoral stem fixation 10 out of 10 and 14.9 out of 17 for femoral stem stability. No reactive lines at the bone-stem interfaces and no subsidence or osteolysis were evident in any of the radiographs. There were 5 periprosthetic femoral fractures, 2 deep infections, 3 dislocations, and 2 aseptic loosening (one each for the femoral stem and acetabular socket). Survivorship of the femoral stem at 10 years was 99% when revision secondary to only aseptic loosening of the stem was the endpoint. It was 96% when failures due to all causes (infection, periprosthetic fracture, and aseptic loosening) were the endpoints. CONCLUSION The MBA femoral prosthesis provides a predictably stable fixation, with excellent mid-term outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Results of 3,668 primary total hip replacements

BACKGROUND AND PURPOSE In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of...

متن کامل

High 10-Year Survival Rate with an Anatomic Cementless Stem (SPS)

BACKGROUND Proximal cementless fixation using anatomic stems reportedly increases femoral fit and avoids stress-shielding. However, thigh pain was reported with the early stem designs. Therefore, a new anatomic cementless stem design was based on an average three-dimensional metaphyseal femoral shape. However, it is unclear whether this stem reduces the incidence of thigh pain. QUESTIONS/PURP...

متن کامل

Cementless femoral fixation in total hip arthroplasty.

Cementless femoral fixation by means of bone ingrowth has been successful in total hip arthroplasty in patients with sufficient bone quality. Consistent bone ingrowth and resultant long-term success involve many factors, including surgical technique, initial mechanical stability achieved at time of implantation, stem design and material, and implant surface. One potential method for achieving f...

متن کامل

A new short uncemented, proximally fixed anatomic femoral implant with a prominent lateral flare: design rationals and study design of an international clinical trial

BACKGROUND Anatomic short femoral prostheses with a prominent lateral flare have the potential to reduce stress-shielding in the femur through a more physiological stress distribution to the proximal femur. We present the design rationale of a new short uncemented, proximally fixed anatomic femoral implant and the study design of a prospective multi-centre trial to collect long-term patient out...

متن کامل

Hydroxyapatite-coated versus grit-blasted femoral stems. a prospective, randomised study using EBRA-FCA.

We have carried out a prospective, randomised study designed to compare the long-term stability of the stem of cementless femoral implants with differing surface configurations. A total of 50 hips (46 patients) was randomised into two groups, according to whether the medullary stem had been grit blasted (GB) or coated with hydroxyapatite (HA). Both femoral prostheses were of the same geometrica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2012