Electrochemiluminescence Detection of Primary Amines Using Tris(bipyridine)ruthenium(III) after Derivatization with Divinylsulfone
نویسندگان
چکیده
Aliphatic primary amines are industrial chemicals with a wide variety of applications. For the determination of these substances, HPLC has recently been used; it has several advantages over other analytical methods, including high selectivity and sensitivity. On the other hand, an electrochemiluminescence (ECL) method has been developed as a highly sensitive method for HPLC detection.)-3 However., there is still no established methodology for the determination of aliphatic primary amines. The Tris(bipyridine)ruthenium(II) (Ru(bpy)32+) ECL system is useful for a selective, sensitive determination of oxalates4'5, indoles1'6, and trialkylamines2'' in biological and pharmaceutical samples. We previously reported that by using this system alicyclic tertiary amines8 were detectable at the pmol level, althouth the CL intensity of aliphatic primary amines was very low compared with that of the tertiary amines; and they could only be detected at a level of about 1000-times lower than that of tertiary amines.' In this paper we discuss the CL detection of some primary amines using a cycloaddition reaction of the amines with divinyl sulfone (DVS) caused by electrogenerated Ru(bpy)33t Furthermore, precolumn derivatization HPLC of the amines using LC postcolumn reaction detection with this CL system is described.
منابع مشابه
Column-switching HPLC determination of mexiletine using tris(bipyridine)ruthenium(III) electrogenerated chemiluminescence and precolumn derivatization with divinylsulfone.
A sensitive HPLC method combined with a column-switching system and tris(bipyridine)ruthenium(III) electrogenerated chemiluminescence (ECL) detection has been developed for the quantitative determination of mexiletine (MEX). MEX was derivatized by divinylsulfone (DVS) and then measured. The optimum conditions for the derivatization reaction were 10 µL of sample solutions, 40 mM DVS (pH 8.0), a ...
متن کاملElectrogenerated chemiluminescence derivatization reagents for carboxylic acids and amines in high-performance liquid chromatography using tris(2,2'-bipyridine)ruthenium(II).
2-(2-Aminoethyl)-1-methylpyrrolidine and N-(3-aminopropyl)pyrrolidine (NAPP) were found to be selective and sensitive derivatization reagents for carboxylic acid by high-performance liquid chromatography (HPLC) with electrogenerated chemiluminescence detection using tris(2,2'-bipyridine)ruthenium(II). Free fatty acids and ibuprofen were used as model compounds of carboxylic acids, and the deriv...
متن کاملDetection of Clindamycin in Pharmaceutical Products using an Electrochemiluminescence Electrode based on a Composite of Ru(bpy)3²+, Eu2O3 Nanoparticle and Chitosan
In this study, the electrochemiluminescence (ECL) interaction of clindamycin and tris(2,2′-bipyridine)ruthenium(II) (Ru(bpy)32+) was used to develop a sensitive tool for the detection of clindamycin based on modifying a glassy carbon electrode (GCE) with nanoparticles of europium oxide. The experiments showed that in the presence of these inorganic nanoparticles (Eu2<...
متن کاملHigh sensitive approach for point mutation detection based on electrochemiluminescence.
An electrochemiluminescence-polymerase chain reaction (ECL-PCR) method for point mutation detection has been developed. The target is amplified using a tris (bipyridine) ruthenium (TBR)-labeled forward and a biotinylated reverse primer. The amplification products are digested with specific restriction enzyme, then captured onto streptavidin-coated paramagnetic beads, and detected by measuring t...
متن کاملSensitive determination of domoic acid using high-performance liquid chromatography with electrogenerated tris(2,2'-bipyridine)ruthenium(III) chemiluminescence detection.
A new sensitive determination method of domoic acid based on the chemiluminescent reaction of tris(2,2'-bipyridine)ruthenium(III) has been developed. The method exhibited good reproducibility. The relative standard deviation of six replicate measurements was 1.6% for 10 ng ml(-1). A calibration graph, based on a standard domoic acid solution, was linear over the range of 1 - 500 ng ml(-1) (coef...
متن کامل