A novel adjunctive cleansing method to reduce colony-forming units on duodenoscopes

نویسندگان

  • Karl Kwok
  • Joseph Chang
  • Simon Lo
  • Andrew Giap
  • Brian Lim
  • Bechien Wu
چکیده

Background and study aims: Endoscopic retrograde cholangiopancreatography-related infections are of increasing global concern due to the emergence of multidrug-resistant bacteria such as carbapenem-resistant enterobacteriaceae (CRE), with bacterial biofilm production postulated as one cause of persistent infection from such virulent organisms. Because N-acetylcysteine (NAC) has been shown to possess antibacterial and biofilm-disruption properties, we aimed to evaluate if NAC would demonstrate clinical utility in reducing the colony forming units (CFU) at the elevator end of a duodenoscope, one of the hardest areas to clean. Patients and methods: This was a pilot study of 16 procedures involving the use of a duodenoscope. After use, the elevator tip of a duodenoscope was cultured and submerged for 30 minutes, either in 20 % NAC (200 mg/mL, intervention) or in sterile water (control). After 30 minutes, the elevator tip was re-cultured. Results: Submersion of the distal end of a duodenoscope in 20 % NAC (200 mg/mL) for 30 minutes resulted in a statistically significant reduction in bacterial colony forming units compared to control (average reduction 41.6 % vs 8.8 %, P = 0.001). There was no visible damage and no optical distortion to the duodenoscope after submersion in NAC. Conclusions: In summary, NAC may be a safe, simple, and useful adjunct to currently available methods of duodenoscope reprocessing. Further research may better define NAC's role in duodenoscope reprocessing, either broadly or specifically after procedures suspected to produce a high risk of bacterial contamination (e. g. choledocholithiasis).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Best practice for patient self-cleaning of urinary drainage bags.

The best practice for cleansing urinary drainage bags (leg and bed) in a hospital setting can be translated for use by clients for self-care within the home setting. Common household bleach containing 5.25% sodium hypochlorite, diluted in a 1:10 ratio with tap water, is a safe and effective method to reduce colony-forming units per milliliter (CFU/ml) to a study-defined acceptable range of 100 ...

متن کامل

Potential use of human stem cell factor as adjunctive therapy for human immunodeficiency virus-related cytopenias.

Hematopoietic dysfunction with peripheral cytopenias is a common complication of human immunodeficiency virus (HIV) infection. Symptomatic anemia is the most common cytopenia and occurs in the presence and absence of myelosuppressive drug therapy such as zidovudine. Drug-induced neutropenia and immune thrombocytopenia are also frequent and occur in up to 50% of acquired immunodeficiency syndrom...

متن کامل

[Comparison of two hand hygiene techniques in peritoneal dialysis patients].

INTRODUCTION Hand hygiene is an important procedure in preventing peritoneal dialysis-related infections. OBJECTIVE To compare the effectiveness of two distinct techniques for hand hygiene in reducing the number of colony-forming units in patients on peritoneal dialysis. MATERIALS AND METHOD Controlled clinical trial. Thirty patients underwent three collections of microbiological flora from...

متن کامل

Effects of 4 hand-drying methods for removing bacteria from washed hands: a randomized trial.

OBJECTIVE To evaluate the effects of 4 different drying methods to remove bacteria from washed hands. SUBJECTS AND METHODS One hundred adult volunteers participated in this randomized prospective study. All bacterial counts were determined using a modified glove-juice sampling procedure. The difference was determined between the amounts of bacteria on hands artificially contaminated with the ...

متن کامل

Sterile Reverse Osmosis Water Combined with Friction Are Optimal for Channel and Lever Cavity Sample Collection of Flexible Duodenoscopes

Introduction Simulated-use buildup biofilm (BBF) model was used to assess various extraction fluids and friction methods to determine the optimal sample collection method for polytetrafluorethylene channels. In addition, simulated-use testing was performed for the channel and lever cavity of duodenoscopes. Materials and methods BBF was formed in polytetrafluorethylene channels using Enterococ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016