The effect of surface finish and interstitial fluid on the cement-in-cement interface in revision surgery of the hip.

نویسندگان

  • G Rudol
  • R Wilcox
  • Z Jin
  • E Tsiridis
چکیده

The mechanical performance of the cement-in-cement interface in revision surgery has not been fully investigated. The quantitative effect posed by interstitial fluids and roughening of the primary mantle remains unclear. We have analysed the strength of the bilaminar cement-bone interface after exposure of the surface of the primary mantle to roughening and fluid interference. The end surfaces of cylindrical blocks of cement were machined smooth (Ra = 200 nm) or rough (Ra = 5 μm) and exposed to either different volumes of water and carboxymethylcellulose (a bone-marrow equivalent) or left dry. Secondary blocks were cast against the modelled surface. Monoblocks of cement were used as a control group. The porosity of the samples was investigated using micro-CT. Samples were exposed to a single shearing force to failure. The mean failure load of the monoblock control was 5.63 kN (95% confidence interval (CI) 5.17 to 6.08) with an estimated shear strength of 36 MPa. When small volumes of any fluid or large volumes were used, the respective values fell between 4.66 kN and 4.84 kN with no significant difference irrespective of roughening (p > 0.05). Large volumes of carboxymethylcellulose significantly weakened the interface. Roughening in this group significantly increased the strength with failure loads of 2.80 kN (95% CI 2.37 to 3.21) compared with 0.86 kN (95% CI 0.43 to 1.27) in the smooth variant. Roughening of the primary mantle may not therefore be as crucial as has been previously thought in clinically relevant circumstances.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cement-Implant Interface Fracture Failure by Crack Initiation Due to Interface Cavity Stress Concentration

Nowadays total joint replacements are widely used in the world, so in average 800,000 joint surgeries are done yearly only in Europe and North America. However implant loosening is and remains as the major issue of all implant failures and therefore causes revision surgery procedures. Studies and experiments have identified poor fixation of implants most likely is the main cause of long term im...

متن کامل

The Use of Antibiotic Impregnated Cement Spacers in the Treatment of Infected Total Joint Replacement: Challenges and Achievements

Two stage total hip arthroplasty revision surgery includes foreign material debridment, insertion of antibiotic impregnatedcement spacer, and finally, reimplantation of the prosthesis. This review has aimed to evaluate the efficacy of antibioticimpregnated cement spacers in infection control and eradication in arthroplasties.A total of 85 articles on total hip arthroplasty wer...

متن کامل

0251 - the Effect of a Silane Coupling Agent on the Alloy/pmma Interface

Introduction: Total joint replacement has long been the most effective treatment for severe arthritis in the hip. The most common clinical problem associated with the surgery is long-term aseptic loosening of the implant. The limited durability of the artificial joint, and the difficulty of revision surgery, have limited the potential applications of this treatment, particularly in younger and ...

متن کامل

The Use of Nanoaccelerator in Cement Slurries in Low Temperature Well Conditions

It has long been known that temperature during circulation and after cement placement is one of the most important parameters for slurry design and the success in cement production. Conventional cements and low density cement slurries usually take a long time to set and cannot provide significant compressive strength. Therefore, it is important to design appropriate low density cement slurries ...

متن کامل

Gentamicin release from old cement during revision hip arthroplasty.

Bone cement containing gentamicin may release antibiotic when fractured during revision operations. Tissue samples taken during surgery may be contaminated by gentamicin and give inaccurate microbiological assessment. We studied five patients in whom cement containing gentamicin had been used in the primary procedure. During revision hip replacement, samples of joint fluid, tissues and cement w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 2  شماره 

صفحات  -

تاریخ انتشار 2011