Titration of propofol for anesthetic induction and maintenance guided by the bispectral index: closed-loop versus manual control: a prospective, randomized, multicenter study.

نویسندگان

  • Ngai Liu
  • Thierry Chazot
  • Antoine Genty
  • Alain Landais
  • Aymeric Restoux
  • Kathleen McGee
  • Pierre-Antoine Laloë
  • Bernard Trillat
  • Luc Barvais
  • Marc Fischler
چکیده

BACKGROUND This report describes a closed-loop titration of propofol target control infusion based on a proportional-differential algorithm guided by the Bispectral Index (BIS) allowing induction and maintenance of general anesthesia and compares this to manual propofol target control infusion. METHODS One hundred sixty-four patients scheduled to undergo elective minor or major surgery were prospectively randomized in a multicenter study into the closed-loop (n = 83) or manual target control infusion group (n = 81). The goal was to reach a BIS target of 50 during induction and to maintain it between 40 and 60 during maintenance. For both groups, remifentanil target control infusion was adjusted manually, and ventilation was without nitrous oxide. RESULTS Closed-loop control was able to provide anesthesia induction and maintenance for all patients. During induction, propofol consumption was lower in the closed-loop group (1.4 +/- 0.5 vs. 1.8 +/- 0.6 mg/kg; P < 0.0001), but the duration was longer (320 +/- 125 vs. 271 +/- 120 s; P < 0.0002). Adequate anesthesia maintenance, defined as the BIS in the range of 40-60, was significantly higher in the closed-loop group (89 +/- 9 vs. 70 +/- 21%; P < 0.0001), with a decrease of the occurrence of BIS less than 40 (8 +/- 8 vs. 26 +/- 22%; P < 0.0001). Time from discontinuation of propofol infusion to tracheal extubation was shorter in the closed-loop group (7 +/- 4 vs. 10 +/- 7 min; P < 0.017). Unwanted somatic events and hemodynamic instability were similar. CONCLUSION Automatic control of consciousness using the BIS is clinically feasible and outperforms manual control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of closed-loop titration of propofol and remifentanil guided by the bispectral monitor in pediatric and adolescent patients: a prospective randomized study.

BACKGROUND This study was designed to assess the feasibility of dual closed-loop titration of propofol and remifentanil guided solely by the Bispectral Index (BIS) monitor in pediatric and adolescent patients during anesthesia. METHODS Children undergoing elective surgery in this single-blind randomized study were allocated into the closed-loop (auto) or manual (manual) group. Primary outcome...

متن کامل

Impact of a preoperative conversational hypnotic session on propofol consumption using closed-loop anesthetic induction guided by the bispectral index

OBJECTIVE The automated administration of propofol in a closed loop could be used to objectively evaluate the nonpharmacological anesthetic action of hypnotherapy. The objective of this study was to evaluate the impact of a conversational hypnosis session on the consumption of propofol for anesthetic induction. DESIGN A randomized, usual care-controlled, single-center, patient-blind trial. ...

متن کامل

Comparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus "standard practice" controlled administration.

BACKGROUND This report describes a new closed-loop control system for propofol that uses the Bispectral Index (BIS) as the controlled variable in a patient-individualized, adaptive, model-based control system, and compares this system with manually controlled administration of propofol using hemodynamic and somatic changes to guide anesthesia. METHODS Twenty female patients, American Society ...

متن کامل

A Multicenter Evaluation of a Closed-Loop Anesthesia Delivery System: A Randomized Controlled Trial.

BACKGROUND Closed-loop systems for anesthesia delivery have been shown to outperform traditional manual control in different clinical settings. The present trial was aimed at evaluating the feasibility and efficacy of Bispectral Index (BIS)-guided closed-loop anesthesia delivery system (CLADS) in comparison with manual control across multiple centers in India. METHODS Adult patients scheduled...

متن کامل

Dexmedetomidine reduces propofol and remifentanil requirements during bispectral index-guided closed-loop anesthesia: a double-blind, placebo-controlled trial.

BACKGROUND The α2-adrenergic agonist dexmedetomidine is a sedative and can be used as an adjunct to anesthetics. Our primary goal was thus to determine the extent to which dexmedetomidine reduces the requirement for propofol and remifentanil. METHODS This double-blinded, randomized study (NCT00921284) used an automated dual closed-loop administration to maintain the Bispectral Index between 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 104 4  شماره 

صفحات  -

تاریخ انتشار 2006