Novel application of low pH-dependent fluorescent dyes to examine colitis

نویسندگان

  • Kazuhiro Ishiguro
  • Takafumi Ando
  • Osamu Watanabe
  • Hidemi Goto
چکیده

BACKGROUND Endoscopy capable of fluorescence observation provides histological information on gastrointestinal lesions. We explored the novel application of low pH-dependent fluorescent dyes for fluorescence observation of crypt structure and inflammatory cell infiltration in the colon. METHODS Low pH-dependent fluorescent dyes were applied to the colonic mucosa of normal mice for observation under fluorescence stereomicroscopy system. We also examined mouse models of colitis, which were induced by trinitrobenzenesulfonic acid, dextran sulfate sodium or interleukin-10 deficiency. RESULTS Topical application of low pH-dependent fluorescent dyes revealed crypts as ring-shaped fluorescent stains by visualizing the mucin granules of goblet cells. Because of the minimal fluorescence intensity of the low pH-dependent fluorescent dyes in phosphate-buffered saline, it was not necessary to wash the mucosa before the fluorescence observation. 4-Nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ) was quicker to achieve complete staining (three minutes) than LysoSensor Green DND-153 and DND-189 (20 minutes). In each type of colitis, NBD-PZ revealed the destruction of the crypts as the disappearance of the ring-shaped fluorescent stains and the infiltration of inflammatory cells as the aggregation of punctate fluorescent stains through visualization of lysosomes. CONCLUSIONS Low pH-dependent fluorescent dyes, especially NBD-PZ, are suitable for topical application to the colonic mucosa and have characteristics that allow for the histological examination of colitis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synthesis, characterization, and textile application of novel disperse dyes

In this paper, two novel alkali clearable disperse dyes were synthesized. 4-flourosulfonyl aniline and 2-nitro-4-flourosulfonyl aniline were utilized as the diazo components and 2- naphthol as the coupling component. The DSC, FTIR, 1HNMR and UV-Vis analyses were used to characterize the synthesized intermediates and dyes. The synthesized dyes were used to dye polyester fibers and their dyeing p...

متن کامل

Improved Fastness Properties of some Novel Triarylmethane Dyes on Acrylic Fibres

In this research, several series of triarylmethane dyes containing one or more terminal methoxy substituents with a variable tertiary amino groups have been used. These dyes have been applied to different substrates by using various methods including transfer printing and then their fastness properties were measured. These dyes shows exceptionally high light fastness (6-7) on acid modified poly...

متن کامل

The Application of Low-Cost Adsorbent for Reactive Blue 19 Dye Removal from Aqueous Solution: Lemna Minor

Background & Aims of the Study: Due to widespread use and adverse effect of dyes, the removal of dyes from effluents is necessary. This study was aimed to remove the reactive blue 19 dye removal from aqueous solution by dried Lemna minor. Materials and Methods:  The effect of various parameters including contact time, solution pH, adsorbent dosage and dye concentrati...

متن کامل

Application of Acaciatortilis Shuck as of Low-cost Adsorbent to Removal of Azo Dyes Reactive Red 198 and Blue 19 from Aqueous Solution

    Background & Aims of the Study: Textile wastewaters are very various in chemical qualities. In other words, these industries are one of the largest producing dyes compounds; therefore their treatment is so complex and difficult. The aim of this study was to evaluate the potential removal of Reactive Red 198 and Blue Reactive 19 from synthetic solution by Acaciatortilis shu...

متن کامل

Microfluidic Devices Made of Uv-curable Glue (noa81) for Fluorescence Detection Based Applications

The UV-curable adhesive NOA81 (Norland Optical Adhesive) is a promising liquid photopolymer for low-cost microfluidic chip production. Different fabrication methods for NOA81 are suggested [1,2]. However, optical characterization for fluorescent based detection systems is missing. We present a comparison of fluorescent emission spectra of various NOA types as well as the time evolution of the s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010