Optimizing electrode sites for segmental bioimpedance measurements.

نویسندگان

  • B H Cornish
  • A Jacobs
  • B J Thomas
  • L C Ward
چکیده

Recent advances in the application of bioelectrical impedance analysis (BIA) have indicated that a more accurate approach to the estimation of total body water is to consider the impedance of the various body segments rather than simply that of the whole body. The segmental approach necessitates defining and locating the physical demarcation between both the trunk and leg and the trunk and arm. Despite the use of anatomical markers, these points of demarcation are difficult to locate with precision between subjects. There are also technical problems associated with the regional dispersion of the current distribution from one segment (cylinder) to another of different cross-sectional area. The concept of equipotentials in line with the proximal aspects of the upper (and lower) limbs along the contralateral limbs was investigated and, in particular, the utility of this concept in the measurement of segmental bioimpedance. The variation of measured segmental impedance using electrode sites along these equipotentials was less than 2.0% for all of the commonly used impedance parameters. This variation is approximately equal to that expected from biological variation over the measurement time. It is recommended that the electrode sites, for the measurement of segmental bioelectrical impedance in humans, described herein are adopted in accordance with the proposals of the NIH Technology Assessment Conference Statement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total Body Water Changes Using Segmental Bioimpedance in Healthy Population with Similar Anthropometry

Electrical bioimpedance was measured in 7 body segments, and also with the standard right-side method, using 11 electrodes at 6 different frequencies in 8 healthy male subjects with similar anthropometry. Our objective was to determine the capability of segmental bioimpedance measurements to estimate small changes of water on each segment (TWsegi) and total body water (TBW) in comparison with t...

متن کامل

Segmental Spectral Decomposition as a Time Persistent Method of BioImpedance Spectroscopy Feature Extraction

BioImpedance Spectroscopy (BIS) have been investigated in many research areas as a method to detect changes in living tissues. However, BIS measurements are known to be hardly reproducible in clinical applications. This article proposes segmental spectral decomposition as a method of extracting reproducible parameters from raw BIS. The efficiency of this method is then compared to conventional ...

متن کامل

Influence of ambient temperature on whole body and segmental bioimpedance spectroscopy measurements

Bioimpedance spectroscopy (BIS) measurements are easy to implement and could be used for continuous monitoring. However, several factors (e.g. environment temperature) influence the measurements limiting the accuracy of the technology. Changes in skin temperature produced by changes in ambient temperature are related with changes in skin blood flow and skin impedance. It is assumed that skin im...

متن کامل

Segment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients.

Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positi...

متن کامل

Dynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis.

Extracellular volume (ECV) of arms, trunk, and legs determined from segmental bioimpedance data in 11 healthy men (31.6 +/- 7 yr) obtained at the end of a 30-min equilibration phase in the supine body position was compared with ECV determined from whole body measurements (ECVWB). ECV was calculated from extracellular resistance (RECV) identified from the bioimpedance spectrum for a range of 10 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 1999