Five-Year Experience of Vitamin E-Diffused Highly Cross-Linked Polyethylene Wear in Total Hip Arthroplasty Assessed by Radiostereometric Analysis.
نویسندگان
چکیده
BACKGROUND Vitamin E-diffused highly cross-linked polyethylene (VEPE) was developed to reduce oxidation without compromising mechanical strength. The purpose of this study was to evaluate VEPE in vivo using radiostereometric analysis (RSA) and patient-reported outcome measures (PROMs). METHODS Fifty-one hips were enrolled. Each patient received a VEPE liner, a porous titanium shell, and an uncemented stem with a 32-mm cobalt-chrome femoral head. Tantalum beads were inserted into the VEPE to measure femoral head penetration using RSA. RSA radiographs and PROMs were obtained preoperatively immediately after surgery, 6 months, 1, 2, 3, and 5 years after surgery. RESULTS Forty-seven hips returned at 3 years, and 42 hip at 5 years. The mean ± standard error of the mean proximal head penetration into the polyethylene was 0.06 ± 0.01 at 5 years. The amount of head penetration did not change significantly with increasing time in vivo. The mean ± standard error of the mean Harris Hip Score was 58 ± 2 preoperatively, which improved significantly to 93 ± 2 at 5 years (P < .001). CONCLUSION The head penetration into VEPE liners was low compared with non-VEPE at 5 years. After settling of the liners in the early period, no significant head penetration occurred from 2- to 5-year follow-up. All PROMs improved significantly from preoperative to postoperative and remained very favorable at 5 years. This study documents the longest-term evaluation of in vivo wear performance of VEPE.
منابع مشابه
Cross-linked polyethylene and bisphosphonate therapy for osteolysis in total hip arthroplasty: a case report.
A 39-year-old woman underwent bilateral total hip arthroplasty with conventional, ethylene oxide-sterilised liners when she was a subject in a radiostereometric analysis study. Within 2 years she had rapid polyethylene wear with aggressive, asymptomatic, and periprosthetic osteolysis on both sides. Oral alendronate therapy halted the progression of osteolysis over a year and revision to cross-l...
متن کاملMigration and head penetration of Vitamin-E diffused cemented polyethylene cup compared to standard cemented cup in total hip arthroplasty: study protocol for a randomised, double-blind, controlled trial (E1 HIP)
INTRODUCTION In vitro, Vitamin-E-diffused, highly cross-linked polyethylene (PE) has been shown to have superior wear resistance and improved mechanical properties when compared to those of standard highly cross-linked PE liners used in total hip arthroplasty (THA). The aim of the study is to evaluate the safety of a new cemented acetabular cup with Vitamin-E-doped PE regarding migration, head ...
متن کاملThe creep and wear of highly cross-linked polyethylene: a three-year randomised, controlled trial using radiostereometric analysis.
The creep and wear behaviour of highly cross-linked polyethylene and standard polyethylene liners were examined in a prospective, double-blind randomised, controlled trial using radiostereometric analysis. We randomised 54 patients to receive hip replacements with either highly cross-linked polyethylene or standard liners and determined the three-dimensional penetration of the liners over three...
متن کاملWear, bone density, functional outcome and survival in vitamin E-incorporated polyethylene cups in reversed hybrid total hip arthroplasty: design of a randomized controlled trial
BACKGROUND Aseptic loosening of total hip arthroplasties is generally caused by periprosthetic bone resorption due to tissue reactions on polyethylene wear particles. In vitro testing of polyethylene cups incorporated with vitamin E shows increased wear resistance. The objective of this study is to compare vitamin E-stabilized highly cross-linked polyethylene with conventional cross-linked poly...
متن کاملBiotribology of a vitamin E-stabilized polyethylene for hip arthroplasty - Influence of artificial ageing and third-body particles on wear.
The objective of our study was to evaluate the influence of prolonged artificial ageing on oxidation resistance and the subsequent wear behaviour of vitamin E-stabilized, in comparison to standard and highly cross-linked remelted polyethylene (XLPE), and the degradation effect of third-body particles on highly cross-linked remelted polyethylene inlays in total hip arthroplasty. Hip wear simulat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 31 6 شماره
صفحات -
تاریخ انتشار 2016