The primary study of low-dose pancreas perfusion by 640- slice helical CT: a whole-organ perfusion
نویسندگان
چکیده
To discuss the feasibility of low-dose whole-pancreas imaging utilizing 640-slice dynamic volume CT.80 patients (40 cases of normal pancreas and 40 patients supposed of having pancreatic carcinoma or focal pancreatic space-occupying lesions were mainly refered) referred for CT pancreas perfusion were enrolled in the study. 80 patients randomly assigned to 3 groups: Group ① (whole sequence). Group ② (odd number sequence). Group ③ (even number group)(Compared to ①, the scanning times and effective radiate dose of ② and ③ decreased about 50% respectively). The head, body, tail of each normal pancreas without any pancreatic disease, lesion and lesion-surrounding areas of each pancreatic cancer were selected as ROI, and tissue peak, blood flow are measured.According to pathology and clinical materials, 27 patients were diagnosed as pancreatic cancer; 40 patients were diagnosed as normal pancreas. The tissue peak and blood flow of the head, body, tail of normal pancreas without any pancreatic disease are 109.63 ± 16.60 and 131.90 ± 41.61, 104.38 ± 19.39 and 127.78 ± 42.52, 104.55 ± 15. 44 and 123.50 ± 33.44 respectively. The tissue peak and blood flow of pancreatic cancer is 59.59 ± 18.20 and 60.00 ± 15.36. For and between each group, there is no significant statistical difference for the tissue peak and blood flow of normal areas of the head, body, tail of normal pancreas. There is statistical difference for the tissue peak and blood flow of lesion and lesion-surrounding areas of pancreatic cancer in each group. However, there is no statistical difference for the tissue peak and blood flow of normal and diseasing areas between 3 groups.Low-dose whole-pancreas perfusion with 640-slice dynamic volume CT is feasible.
منابع مشابه
Whole-Organ CT Perfusion of the Pancreas: Impact of Iterative Reconstruction on Image Quality, Perfusion Parameters and Radiation Dose in 256-Slice CT-Preliminary Findings
BACKGROUND This study was performed to assess whether iterative reconstruction can reduce radiation dose while maintaining acceptable image quality, and to investigate whether perfusion parameters vary from conventional filtered back projection (FBP) at the low-tube-voltage (80-kVp) during whole-pancreas perfusion examination using a 256-slice CT. METHODS 76 patients with known or suspected p...
متن کاملThe Clinical Application of One-Stop Examination with 640-Slice Volume CT for Nutcracker Syndrome
BACKGROUND To investigate the relationship between the level of left renal vein (LRV) compression and changes in the perfusion of the left kidney in patients with nutcracker syndrome (NCS) by one-stop whole-organ perfusion imaging of bilateral kidneys using 640-slice volume CT. METHODS Twelve patients, clinically diagnosed with NCS, were subjected to one-stop examination of kidneys. Angiograp...
متن کاملComparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...
متن کاملEstimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity
OBJECTIVE We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. MATERIALS AND METHODS An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D-Perfusion-CT. Phantom measurements were performed on a 128-slice single-source scanner in adaptive ...
متن کاملDetermination of Uterus Absorbed Dose by Patients following Myocardial Perfusion Scan using TLD and Conjugate View Methods
Introduction: The determination of patient’s absorbed dose is the first step of radiation protection which depends on the quantification of organ activity in nuclear medicine. The aim of the present study was to determine the absorbed dose by patient’s uterus following myocardial perfusion scan with 99mTC-sestamibi using Theroluminescnce dosimetry (TLD) and conjugate-view metho...
متن کامل