Torsion strength of biodegradable and titanium screws: a comparison.

نویسندگان

  • Gerrit J Buijs
  • Eduard B van der Houwen
  • Boudewijn Stegenga
  • Rudulf R M Bos
  • Gijsbertus J Verkerke
چکیده

PURPOSE To determine 1) the differences in maximum torque between 7 biodegradable and 2 titanium screw systems, and 2) the differences of maximum torque between "hand tight" and break of the biodegradable and the titanium osteofixation screw systems. MATERIALS AND METHODS Four oral and maxillofacial surgeons inserted 8 specimens of all 9 screw systems in polymethylmethacrylate plates. The surgeons were instructed to insert the screws as they would do in the clinic (hand tight). The data were recorded by a torque measurement meter. A PhD resident inserted 8 specimens of the same set of 9 screw systems until fracture occurred. Likewise, the maximum applied torque was recorded. RESULTS 1) The mean maximum torque of the 2 titanium screw systems was significantly higher than that of the 7 biodegradable screw systems, and 2) the mean maximum torque for hand tight was significantly lower than for break in 2 biodegradable, and both titanium screw systems. CONCLUSIONS Based on the results, we conclude that the 1.5 mm and 2.0 mm titanium screw systems still present the highest torque strength compared with the biodegradable screw systems. When there is an intention to use biodegradable screws, we recommend the use of 2.0 mm BioSorb FX (Linvatec Biomaterials Ltd, Tampere, Finland), 2.0 mm LactoSorb (Walter Lorenz Surgical Inc, Jacksonville, FL), or the larger 2.5 mm Inion (Inion Ltd, Tampere, Finland) screws.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An investigation of tensile strength of Ti6Al4V titanium screw inside femur bone using finite element and experimental tests

The geometric optimization of orthopedic screws can considerably increase their orthopedic efficiency. Due to the high geometric parameters of orthopedic screws, a finite element simulation is an effective tool for analyzing and forecasting the effect of the parameters on the load-bearing capacity of different types of screws and bones. Thus, in the present study, the tensile strength of a typi...

متن کامل

Initial fixation strength of modified patellar tendon grafts for anatomic fixation in anterior cruciate ligament reconstruction.

Recently it has been shown that anatomic tibial graft fixation in anterior cruciate ligament (ACL) reconstruction is preferable in order to increase isometry and knee stability. To facilitate anatomic patellar tendon graft fixation, customized graft length shortening is necessary. The purpose of this study was to compare the initial fixation strength of four different shortened patellar tendon ...

متن کامل

A Fracture Analysis of Ti-10Mo-8V-1Fe-3.5Al Alloy Screws during Assembly

Titanium screws have properties that make them ideal for applications that require both a high strength-to-weight ratio and corrosion resistance, such as fastener applications for aviation and aerospace. The fracture behavior of Ti-10Mo-8V-1Fe-3.5Al (TB3) alloy screws during assembly was explored. Besides visual examination, other experimental techniques used for the investigation are as follow...

متن کامل

Comparison of the long-term clinical performance of a biodegradable and a titanium fixation system in maxillofacial surgery: A multicenter randomized controlled trial

BACKGROUND Biodegradable fixation systems could reduce or eliminate problems associated with titanium removal of implants in a second operation. AIM The aim of this study was to compare the long-term (i.e. >5 years postoperatively) clinical performance of a titanium and a biodegradable system in oral and maxillofacial surgery. MATERIALS AND METHODS The present multicenter Randomized Control...

متن کامل

Biodegradable Magnesium Screws Accelerate Fibrous Tissue Mineralization at the Tendon-Bone Insertion in Anterior Cruciate Ligament Reconstruction Model of Rabbit

The incorporation of tendon graft into bone tunnel is one of the most challenging clinical issues in anterior cruciate ligament (ACL) reconstruction. As a biodegradable metal, Mg has appropriate mechanical strength and osteoinductive effects, thus may be a promising alternative to commercialized products used for graft fixation. Therefore, it was hypothesized that Mg based interference screws w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons

دوره 65 11  شماره 

صفحات  -

تاریخ انتشار 2007