Suggested Guidelines for Assessment of DG Unintentional Islanding Risk
نویسندگان
چکیده
As increasing numbers of Distributed Generation (DG) systems are connected to utility systems, distribution engineers are becoming increasingly interested in evaluating the risk of unintentional islanding. Utilities desire to keep their systems secure, while not imposing unreasonable burdens on customers wishing to connect DG. However, utility experience with these systems is still relatively sparse, so distribution engineers often are uncertain as to when additional protective measures, such as direct transfer trip, are needed to avoid unintentional islanding. Utilities tend to err on the side of caution, which in some cases may lead to the unnecessary requirement of additional protection. The purpose of this document is to provide distribution engineers with guidance on when additional measures or a more in-depth evaluation may be prudent. The guide also describes situations in which utilities may be able to ascertain that the risk of an unintentional island is extremely low and no additional mitigation or study are needed. The goal is to reduce the unnecessary application of additional protection for DG interconnection. While the content applies to any DG, this document has a focus on photovoltaic (PV) installations.
منابع مشابه
A Hybrid Anti-islanding Method for Inverter-Based Distributed Generation
Nowadays, high penetration of Distributed Generations (DG)s in power systems caused some protection issues. One of these issues is unintentional islanding. As regards IEEE 1547 standard, this situation must be recognized immediately, and DG must be separated from the load in less than 2 seconds. In this paper, to detection of islanding in an inverter-based distributed generation, a new hybrid m...
متن کاملAn Overview on Microgrid Concept with Special Focus on Islanding Protection Issues
Subscriber service is not feasible in the construction of large-scale traditional networks with the aim of providing more services. The high distance between production and consumption requires the definition of a transmission network as a challenging intermediary. The cost of transmission network and the risk associated with it cannot be ignored at all. The idea of a microgrid, which began wit...
متن کاملIslanding Detection for Photovoltaic Inverters Using the Sandia Frequency Shift Method
The connection of inverters for distributed generation photovoltaic systems to the distribution network creates situations of risk to the loads that are connected to the point of common coupling (PCC) and personals who maintain the power grid. A risk that should be avoided is the supply of electricity, by one or more inverters, to the distribution network after disconnecting the main power grid...
متن کاملA Novel Passive Method for Islanding Detection in Microgrids
Integration of distributed generations (DGs) in power grids is expected to play an essential role in the infrastructure and market of electrical power systems. Microgrids are small energy systems, capable of balancing captive supply and requesting resources to retain stable service within a specific boundary. Microgrids can operate in grid-connected or islanding modes. Effective islanding detec...
متن کاملA New Protection System for Islanding Detection in LV Distribution Systems
The growth of penetration of Distributed Generators (DGs) is increasing the risk of unwanted islanded operation in Low Voltage (LV) distribution systems. In this scenario, the existing anti-islanding protection systems, installed at the DG premises and based on classical voltage and frequency relays, are no longer effective, especially in the cases of islands characterized by a close match betw...
متن کامل