Impact of novel balloon catheter on static balloon atrial septostomy with double balloon technique in infants with congenital heart disease.
نویسندگان
چکیده
BACKGROUND The aim of this study was to investigate the feasibility of static balloon atrial septostomy (BAS) with the double balloon technique for infants. TMP PED balloon catheter, newly designed for static BAS in small children, was used in 3 infants. The balloon catheter has a low profile, short and round shoulder, and smooth deflation without slippage. METHODSANDRESULTS Three infants (transposition of the great arteries, n=2; pulmonary atresia with intact ventricular septum, n=1) underwent static BAS with double balloon for restrictive interatrial communication between December 2014 and March 2015. Hemodynamic and echocardiographic assessment was done before and after the procedure. Pressure gradient between left and right atrium decreased from 6, 7 and 9 mmHg to 2, 2 and 1 mmHg, respectively. Oxygen saturation in systemic artery increased from 72, 68 and 73% to 78, 70 and 79%, respectively. Maximum defect diameter increased from 3.5, 3.0 and 3.3 mm to 6.6×5.2, 9.0×6.2 and 8.1×5.1 mm, respectively. No complication was recorded. CONCLUSIONS Static BAS with double balloon technique using the novel TMP PED balloon catheter was safe and effective in producing sufficient interatrial communication for 8-20 weeks in infants. Static BAS is a promising procedure to create interatrial communication in infants.
منابع مشابه
سپتوستومی دهلیزی با راهنمایی اکوکاردیوگرافی: گزارش هشت بیمار
Background: Balloon atrial septostomy is an emergent procedure in pediatric cardiology. Nowadays, most patients in need of the procedure have acceptable outcomes after surgical repair. Thus, it is important to perform this procedure as safe as possible. By performing early arterial switch operation and prostaglandin infusion, the rate of balloon atrial septostomy has markedly decreased. Howeve...
متن کامل[Echocardiographic monitoring of balloon atrial septostomy].
OBJECTIVE To assess balloon atrial septostomy monitored with echocardiography. METHODS From August 1997 to January 2004, 31 infants with congenital heart diseases indicated for balloon atrial septostomy underwent the procedure with exclusive echocardiographic monitoring. Success was defined as the obtainment of an atrial septal defect diameter > 4 mm and ample mobility of its margins. RESUL...
متن کاملBalloon atrial septostomy under two dimensional echocardiographic control.
Two dimensional echocardiography has been used to guide balloon atrial septostomy in five cases of transposition of the great arteries. A single lumen balloon catheter was used. The catheter can be accurately located within the left atrium before inflation of the balloon, thus avoiding some of the traumatic accidents possible during septostomy. The balloon can be observed creating the atrial de...
متن کاملBalloon septostomy for transposition of the great arteries.
Transposition of the great arteries is not a rare anomaly in infancy. Campbell and Suzman (1951) found an incidence of over 6 per cent among 400 cases of cyanotic heart disease. Among 138 cases of congenital heart disease under the age of 6 months, Coleman (1965) found that 27 had transposition of the great arteries. The anomaly is characterized by a short life and, with a few exceptions , deat...
متن کاملBalloon embolization during atrial septostomy.
SUMMARY The case of an infant with complete transposition is presented. Embolization occurred from a balloon catheter used in performing a Rashkind septostomy. Additional Indexing Words: Oxygenation Renal infarction T HE USE of atrial septostomy as a temporary means of improving systemic oxygenation in infants with transposition of the great vessels was introduced by Rashkind and Miller in 1966...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 79 11 شماره
صفحات -
تاریخ انتشار 2015