A metallic microcantilever electric contact probe array incorporated in an atomic force microscope

نویسنده

  • T. Ondarçuhu
چکیده

We present the realization and performance of a multiprobe microcontactor made of an array of metallic microcantilevers inserted in an atomic force microscope ~AFM!. This instrument permits simultaneous AFM imaging and electrical characterization of nanoscale devices. It is therefore well adapted for future generations of molecular devices. The probes are 2-mm-wide metallic cantilevers that are brought in contact with 3 mm33 mm metallic pads of a nanocircuit using a nanopositioning table. The performance of the instrument, tested on mesoscopic metallic wires and carbon nanotubes, shows that the reproducibility of the electrical contact between the probes and the circuit is better than 99.2%. © 2000 American Institute of Physics. @S0034-6748~00!00305-1#

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study of the size-dependant vibration behavior of an AFM microcantilever with a sidewall probe

In this paper, the resonant frequency and sensitivity of an atomic force microscope (AFM) with an assembled cantilever probe (ACP) are analyzed utilizing the modified couple stress theory. The proposed ACP comprises a horizontal microcantilever, an extension and a tip located at the free end of the extension, which make AFM capable of scanning the sample sidewall. First, the governing different...

متن کامل

The effect of intrinsic instability of cantilever on static mode atomic force spectroscopy.

We show that the static force spectroscopy curve taken in an atomic force microscope is significantly modified due to presence of intrinsic cantilever instability which occurs as a result of its movement in a nonlinear force field. This instability acts in tandem with such instabilities as water bridge or molecular bond rupture and makes the static force spectroscopy curve (including 'jump-off-...

متن کامل

Sensitivity analysis of a caliper formed atomic force microscope cantilever based on a modified couple stress theory

A relationship based on the modified couple stress theory is developed to investigate the flexural sensitivity of an atomic force microscope (AFM) with assembled cantilever probe (ACP). This ACP comprises a horizontal cantilever, two vertical extensions and two tips located at the free ends of the extensions which form a caliper. An approximate solution to the flexural vibration problem is obta...

متن کامل

Sensitivity analysis of a caliper formed atomic force microscope cantilever based on a modified couple stress theory

A relationship based on the modified couple stress theory is developed to investigate the flexural sensitivity of an atomic force microscope (AFM) with assembled cantilever probe (ACP). This ACP comprises a horizontal cantilever, two vertical extensions and two tips located at the free ends of the extensions which form a caliper. An approximate solution to the flexural vibration problem is obta...

متن کامل

Study of the flexural sensitivity and resonant frequency of an inclined AFM cantilever with sidewall probe

The resonant frequency and sensitivity of an atomic force microscope (AFM) cantilever with assembled cantilever probe (ACP) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. The proposed ACP comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the AFM capable of topography at sidew...

متن کامل