Finite-element analysis of stress in the canine diaphragm.

نویسندگان

  • S S Margulies
  • G T Lei
  • G A Farkas
  • J R Rodarte
چکیده

Stress in the diaphragm, transdiaphragmatic pressure, and diaphragm shape are interrelated by a balance of forces. Using precise in vivo measurements of diaphragm shape and transdiaphragmatic pressure distribution in combination with finite-element analysis (ANSYS), we determined the direction and magnitude of stress in the passive diaphragm at relaxation volume. Lead spheres sutured along muscle bundles identified muscle bundle location and orientation in vivo. The x, y, and z coordinates of the lead spheres and entire surface of the diaphragm, excluding the zone of apposition, were determined to within 1.4 mm. Thin shell elements were used to construct a finite-element model of the diaphragm with a 2.1- to 4.2-mm internodal spacing. The diaphragm was assumed to have a uniform thickness of 2.5 mm, and magnitude and direction of the principal stresses were computed. The results show that 1) diaphragm stress is nonuniform and anisotropic (i.e., varies both with location on diaphragm surface and direction examined), 2) largest stress (sigma 1) is aligned with muscle bundles and is two to four times larger than sigma 2 (perpendicular to sigma 1 in diaphragm plane), and 3) stress along the muscle bundles is larger in vivo under conditions of biaxial stress than at same length in vitro under uniaxial stress. Although diaphragm stress and tension have often been assumed to be uniform, our finding that stress is oriented primarily along the muscle fibers should be considered in future models of the diaphragm.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Design of Mems piezoresistive pressure sensor

The electromechanical analysis of a piezoresistive pressure microsensor with a square-shaped diaphragm for low-pressure biomedical applications is presented. This analysis is developed through a novel model and a finite element method (FEM) model. A microsensor with a diaphragm 1000 „m length and with thickness=400 µm is studied. The electric response of this microsensor is obtained with applyi...

متن کامل

Accurate Determination of the Pull-in Voltage for MEMS Capacitive Microphone with Clamped Square Diaphragm

Accurate determination of the pull-in, or the collapse voltage is critical in the design process. In this paper an analytical method is presented that provides a more accurate determination of the pull-in voltage for MEMS capacitive devices with clamped square diaphragm. The method incorporates both the linearized modle of the electrostatic force and the nonlinear deflection model of a clamped ...

متن کامل

Accurate Model of Capacitance for MEMS Sensors using Corrugated Diaphragm with Residual Stress

In this paper we present a new model for calculating the capacitance of MEMS sensor with corrugated diaphragm. In this work the effect of residual stress is considered on deflection of diaphragm and capacitance of sensor. First, a new analytical analyzes have been carried out to derive mathematic expressions for central deflection of corrugated diaphragm and its relationship with residual stres...

متن کامل

Analytical Analysis of Capacitive Pressure Sensor with Clamped Diaphragm (RESEARCH NOTE)

Abstract   In this paper analytical analysis of capacitive pressure sensor with clamped diaphragm is presented. Mechanical and electrical properties of the sensor are theoretically analyzed based on theory of thin plates with small deflection and the results are evaluated by use of finite element analysis. The central deflection and capacitance values under uniform external pressure are calcula...

متن کامل

Modelling of Resonance Frequency of MEMS Corrugated Diaphragm for Capacitive Acoustic Sensors (TECHNICAL NOTE)

In this paper, a new model for resonance frequency of clamped circular corrugated diaphragm has been presented. First, an analytical analyzes has been carried out to derive mathematic expressions for mechanical sensitivity of diaphragm with residual stress. Next by using Rayleigh's method we present mathematical model to calculate the resonance frequency of corrugated diaphragm and investigate ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 76 5  شماره 

صفحات  -

تاریخ انتشار 1994