Iris-supported phakic lenses (rigid vs foldable version) for treating moderately high myopia: randomized paired eye comparison.

نویسندگان

  • Julien Coullet
  • José-Luis Guëll
  • Pierre Fournié
  • Hélène Grandjean
  • Javier Gaytan
  • Jean-Louis Arné
  • François Malecaze
چکیده

PURPOSE To compare refractive performance of Artisan (Ophtec, Groningen, The Netherlands) or Verisyse phakic intraocular lens and its foldable version, Artiflex (Ophtec), for the correction of moderately high myopia. DESIGN Randomized pilot study. METHODS setting: Institutional practice. patient population: Thirty-one patients with myopia that ranged from -6 to -14 diopters (D). interventional procedure: One eye was implanted with an Artisan phakic intraocular lens (PIOL) and the other with an Artiflex PIOLs. main outcome measures: Primary outcome measure was the percentage of eyes with uncorrected visual acuity (UCVA) of >20/40 at one year after the operation. Main secondary outcome measures were the safety index, the change of two lines or more of best spectacle-corrected visual acuity (BSCVA) and the endothelial cell count. RESULTS No intraoperative complications were noticed. One year after surgery, the percentage of eyes with UCVA of >20/40 was 51.6% (16/31 patients) for Artisan-treated eyes and 77.4% (24/31 patients) for Artiflex-treated eyes (P = .033). One month after surgery, this same percentage was 42.9% (13/31 patients) and 77.4% (24/31 patients), respectively (P = .004). The safety index at one year was 1.13 +/- 0.24 for Artisan-treated eyes and 1.12 +/- 0.21 for Artiflex-treated eyes, which is a difference that was not statistically significant (P = 0.742). At one year after surgery, the changes of two lines or more of BSCVA and the endothelial cell loss were similar for both groups. CONCLUSION To correct moderately high myopia, the Artiflex lens provides a faster visual recovery and a better UCVA than does the Artisan lens. The safety of the lens should be supported by an enlarged sample size and a longer follow-up period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy and safety of iris-supported phakic lenses (Verisyse) for treating moderately high myopia.

AIM To evaluate efficacy and safety of iris-supported phakic lenses (Verisyse) for treating moderately high myopia. METHODS This prospective clinical study included 40 eyes from 29 patients, who underwent implantation of Verisyse for correction of myopia from -6.00 to -14.50 diopters (D) in the Eye Clinic ''Svjetlost'', Sarajevo, from January 2011 to January 2014. Uncorrected distance visual ...

متن کامل

Comparison of Toric Foldable Iris-Fixated Phakic Intraocular Lens Implantation and Limbal Relaxing Incisions for Moderate-to-High Myopic Astigmatism

PURPOSE To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. MATERIALS AND METHODS The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixa...

متن کامل

Position of rigid and foldable iris-fixated myopic phakic intraocular lenses evaluated by Scheimpflug photography.

PURPOSE To evaluate the postoperative intraocular positional stability of 1 rigid poly(methyl methacrylate) (PMMA) phakic intraocular lens (pIOL) model and 2 foldable polysilicone-PMMA iris-fixated pIOL models. SETTING Department of Ophthalmology, Johann Wolfgang Goethe-University Frankfurt am Main, Germany. METHODS One of 3 iris-fixated pIOL models (Artisan, Artiflex I, and Artiflex II, Op...

متن کامل

ICL versus Veriflex phakic IOL for treatment of moderately high myopia: randomized paired-eye comparison.

PURPOSE To compare the objective and subjective outcome of implantable collamer lenses (ICLs; Staar Surgical, Monrovia, CA) versus Veriflex lenses (AMO, Santa Ana, CA) for the correction of moderately high myopia. METHODS A prospective randomized comparative eye study was performed on 24 patients with bilateral myopia that ranged from -6 to -14.5 diopters (D). One eye was implanted with an IC...

متن کامل

Short-term follow-up after implantation of a foldable iris-fixated intraocular lens in phakic eyes.

OBJECTIVE To evaluate efficiency, predictability, stability, complications, and patient satisfaction after implantation of a foldable iris-fixated phakic intraocular lens (PIOL) for the correction of myopia. DESIGN Prospective, nonrandomized, comparative (self-controlled) trial. PARTICIPANTS Forty-one eyes of 22 myopic patients aged 18 to 56 years (mean, 36 years) with average sphere of -8....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of ophthalmology

دوره 142 6  شماره 

صفحات  -

تاریخ انتشار 2006