Concordance between side-stream end-tidal carbon dioxide and arterial carbon dioxide partial pressure in respiratory service setting.

نویسندگان

  • Grace T S Law
  • C Y Wong
  • C W Kwan
  • K Y Wong
  • F P Wong
  • H N Tse
چکیده

OBJECTIVE To explore the correlation and concordance between end-tidal carbon dioxide and arterial carbon dioxide partial pressure, and confirm the experience of the general consensus among service environments. DESIGN A prospective cross-sectional analysis. SETTING Two respiratory service units in Hong Kong. PARTICIPANTS Two hundred respiratory patients were recruited, in whom 219 sets of observations were recorded. Patients deemed to require arterial blood gas determination also had their end-tidal carbon dioxide partial pressure measured at that time, using two LifeSense LS1-9R Capnometers. MAIN OUTCOME MEASURES The agreement of end-tidal carbon dioxide partial pressure and arterial carbon dioxide partial pressure was studied by correlation coefficients, mean and standard deviation of their difference, and the Bland-Altman plot. RESULTS Overall, the correlation was low and insignificant (r=0.1185, P=0.0801). The mean of the difference was 7.2 torr (95% confidence interval, 5.5-8.9) and significant (P<0.001). The limits of agreement by Bland-Altman analysis were -18.1 to 32.5 torr, which were too large to be acceptable. In the sub-group on room air, the mean difference was reduced to 2.26 torr, the correlation between end-tidal carbon dioxide partial pressure and arterial carbon dioxide partial pressure was 0.2194 (P=0.0068), though statistically significant, the extent of correlation was still low. CONCLUSION End-tidal carbon dioxide partial pressure did not show significant correlation or concordance with arterial carbon dioxide partial pressure, especially when supplemental oxygen was used. End-tidal carbon dioxide partial pressure currently cannot replace arterial blood gas measurement as a tool for monitoring arterial carbon dioxide partial pressure. Possible reasons for the discrepancy with previous studies include small sample size in previous studies, lack of research facilities in service settings, and publication bias against negative studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concordance between side-stream end-tidal carbon dioxide and arterial carbon dioxide partial pressure in respiratory service setting

Non-invasive monitoring of arterial oxygen using percutaneous pulse oximetry is well established. Although some studies show a good correlation of transcutaneous end-tidal carbon dioxide partial pressure (PetCO2) with arterial carbon dioxide partial pressure (PaCO2), they were performed in research settings and involved restricted populations such as paediatric, accident and emergency, or inten...

متن کامل

Investigating the Relationship Between End Tidal Carbon Dioxide and Arterial Carbon Dioxide Pressure in Patients With Respiratory Distress Referred to the Emergency Room of Hazrat Rasool Akram Hospital

Background: Measuring End-Tidal Carbon Dioxide (ETCO-2) can be a non-invasive, fast, and reliable method to predict partial pressure of carbon dioxide (PaCO2) in patients with respiratory distress. This method, which can be a suitable substitute to measure PaCO2, is being used in many emergency rooms and operating rooms in developed countries, but its exact relationship with PaCO2 has not been ...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

Standardization and Validation of Non-invasive Monitoring of End Tidal Carbon Dioxide in Neonates via Nasal Cannula: An Observational Study

Background: Carbon dioxide (CO2) is a by-product of cellular metabolism, which could be considered as a reflection of metabolism, circulation, and ventilation. Arterial blood gas analysis (ABG) is the gold standard of monitoring for CO2. However, is an expensive method leading to blood loss and iatrogenic anemia. In addition, each sample is only a...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hong Kong medical journal = Xianggang yi xue za zhi

دوره 15 6  شماره 

صفحات  -

تاریخ انتشار 2009