Bias-Voltage Stabilizer for HVHF Amplifiers in VHF Pulse-Echo Measurement Systems

نویسندگان

  • Hojong Choi
  • Chulwoo Park
  • Jungsuk Kim
  • Hayong Jung
چکیده

The impact of high-voltage-high-frequency (HVHF) amplifiers on echo-signal quality is greater with very-high-frequency (VHF, ≥100 MHz) ultrasound transducers than with low-frequency (LF, ≤15 MHz) ultrasound transducers. Hence, the bias voltage of an HVHF amplifier must be stabilized to ensure stable echo-signal amplitudes. We propose a bias-voltage stabilizer circuit to maintain stable DC voltages over a wide input range, thus reducing the harmonic-distortion components of the echo signals in VHF pulse-echo measurement systems. To confirm the feasibility of the bias-voltage stabilizer, we measured and compared the deviations in the gain of the HVHF amplifier with and without a bias-voltage stabilizer. Between -13 and 26 dBm, the measured gain deviations of a HVHF amplifier with a bias-voltage stabilizer are less than that of an amplifier without a bias-voltage stabilizer. In order to confirm the feasibility of the bias-voltage stabilizer, we compared the pulse-echo responses of the amplifiers, which are typically used for the evaluation of transducers or electronic components used in pulse-echo measurement systems. From the responses, we observed that the amplitudes of the echo signals of a VHF transducer triggered by the HVHF amplifier with a bias-voltage stabilizer were higher than those of the transducer triggered by the HVHF amplifier alone. The second, third, and fourth harmonic-distortion components of the HVHF amplifier with the bias-voltage stabilizer were also lower than those of the HVHF amplifier alone. Hence, the proposed scheme is a promising method for stabilizing the bias voltage of an HVHF amplifier, and improving the echo-signal quality of VHF transducers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compact CMOS IR-UWB transmitter using variable-order Gaussian pulse generator

ELECT An area-efficient CMOS impulse radio ultra-wideband (IR-UWB) transmitter capable of generating variable orders of Gaussian pulses is presented. The core of the pulse generator is constructed using the cascade connection of RC differentiator networks separated by tunable amplifiers. Tuning the bias current of the amplifier using a voltage-controlled current-source allows for generation of ...

متن کامل

The Design of CMOS Continuous-Time VHF Current and Voltage-Mode Lowpass Filters with Q-Enhancement C - Solid-State Circuits, IEEE Journal of

In this paper, very high frequency (VHF) current and voltage biquadratic lowpass filters implemented directly by the linear wideband finite-gain current and voltage amplifiers, respectively, are proposed and analyzed. A new Q-enhancement circuit which consists of a finite-gain wideband tunable voltage amplifier and a Miller capacitor is also proposed. It can increase the maximum-gain frequency ...

متن کامل

Parametric nanomechanical amplification at very high frequency.

Parametric resonance and amplification are important in both fundamental physics and technological applications. Here we report very high frequency (VHF) parametric resonators and mechanical-domain amplifiers based on nanoelectromechanical systems (NEMS). Compound mechanical nanostructures patterned by multilayer, top-down nanofabrication are read out by a novel scheme that parametrically modul...

متن کامل

Keysight Technologies Simulation and Measurement-based X-parameter Models for Power Amplifiers with Envelope Tracking

Static X-parameter (XP) models for RF power amplifiers (PAs), derived from both simulations and nonlinear vector network analyzer (NVNA) measurements, are investigated for the prediction of PA performance under dynamic signal conditions such as in envelope tracking (ET). The instantaneous AM-AM, AM-PM and PAE predictions of XP models extracted from simulation are compared under ET dynamic signa...

متن کامل

S1: Hardware considerations

DStat relies on three op-amps: the control and buffer amplifiers in the potentiostat (U1 and U2 in Fig. 2(c) in the main text) and the transimpedance amplifier in the current measurement circuit (U3 in Fig. 3(b) in the main text). In DStat, these amplifiers are the LMP7702 (Texas Instruments, Dallas TX, USA) for control and buffer and LMP7721 (Texas Instruments) for transimpedance, respectively...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017