A new procedure for bovine milk digestion in a focused microwave oven: gradual sample addition to pre-heated acid.
نویسندگان
چکیده
Milk samples can be efficiently digested using a focused microwave oven, however the conventional procedure of addition of concentrated acids to the liquid sample leads to digestates with elevated acidity and residual carbon concentrations. In this work a focused microwave oven was applied for acid digestion of bovine milk samples using a conventional and an alternative procedure based on gradual sample addition to hot and concentrated acids. A two-level 2(3) full factorial design experiment with eight runs was carried out to evaluate the optimum experimental conditions for reducing both the residual carbon and the final acidity of digestates. The three studied parameters were: temperature of the digestion medium for sample addition, addition of sulfuric acid before the sample or during the first step, and number of aliquots of the sample gradually added. The best conditions were attained by adding small aliquots of milk (ten-fold a volume of 0.5ml added during 5.0min) to a digestion mixture containing 3.0ml nitric acid plus 1.0ml sulfuric acid heated at 105 degrees C. It was demonstrated that the digestion efficiency of the alternative procedure was better than the conventional procedure, i.e. 98 and 80%, respectively. The alternative procedure was applied for determination of Ba, Ca, Cu, K, Mg, Na, P, and Zn in whole and non-fat bovine milk. The accuracy was proved using two certified reference materials (whole and non-fat milk powder).
منابع مشابه
Zinc (Zn) Analysis in Milk by Microwave Oven Digestion and Differential Pulse Anodic Stripping Voltametry (DPASV) Technique
Milk is very important component of human diet. The presence of over limit of heavy metal in milk may create significant health problems. In the present study, the direct determination of Zinc (Zn) heavy metal in milk samples of different brands was carried out by differential pulse anodic stripping Voltammetric technique at Hanging Mercury Drop Electrode (HMDE). Milk samples were processed by ...
متن کاملDigestion of plastic materials for the determination of toxic metals with a microwave oven for household use.
A rapid sample-digestion method for the determination of toxic metals, cadmium, chromium, and lead, in polyethylene and polyvinyl chloride has been developed by using a microwave oven for household use. An appropriate amount of the sample taken in a PTFE decomposition vessel was mixed with nitric acid or nitric and sulfuric acids. The vessel was heated in a microwave oven by a predetermined ope...
متن کاملDigestion of biological materials using the microwave-assisted sample combustion technique
In this study a procedure for sample digestion based on sample combustion assisted by microwave radiation is proposed. Combustion is started by microwave radiation in the presence of oxygen under pressure using ammonium nitrate as aid for ignition. The system was adapted in a microwave oven with quartz closed vessels. A quartz piece is used simultaneously as a sample holder and as protection to...
متن کاملOnline microwave D-cleavage LC-ESI-MS/MS of intact proteins: site-specific cleavages at aspartic acid residues and disulfide bonds.
An online nonenzymatic digestion method utilizing a microwave-heated flow cell and mild acid hydrolysis at aspartic acid (D) for rapid protein identification is described. This methodology, here termed microwave D-cleavage, was tested with proteins ranging in size from 5 kDa (insulin) to 67 kDa (bovine serum albumin) and a bacterial cell lysate ( Escherichia coli). A microwave flow cell consist...
متن کاملEvidence for the Absence of Amino Acid ,Isomerization in Microwave-Heated Milk and Infant Formulas
According to a recent paper (Lubec et al., 1989), microwave heating of milk or reconstituted infant formulas could induce the inversion of amino acid residues to a significantly higher extent than conventional heating. In this study, UHT milk and three different infant formulas were heated under two sets of conditions: 600 W for 3 min and 70 W for 20 min. When the proportions of D-amino acids w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Talanta
دوره 65 2 شماره
صفحات -
تاریخ انتشار 2005