Heparin--Mn2+ quantitation of high-density-lipoprotein cholesterol: an ultrafiltration procedure for lipemic samples.

نویسندگان

  • G R Warnick
  • J J Albers
چکیده

We describe a modified heparin--Mn2+ procedure for high-density-lipoprotein cholesterol quantitation, especially in lipemic samples. High-density-lipoproteins may be estimated as cholesterol remaining in plasma supernates after precipitation of other lipoproteins by heparin and Mn2+ treatment. However, in lipemic samples or those from non-fasting individuals, the lower density of the precipitated chylomicrons, very-low-, and low-density-lipoproteins frequently prevents their sedimentation by the usual low-speed centrifugation, and high-density-lipoprotein cholesterol thus is overestimated in the resulting turbid supernates. Sedimentation is improved by a twofold increase in Mn2+ concentration to 92 mmol/liter. The procedure reported here produced clear supernates in more than 95% of samples tested. Any remaining turbid supernates can be cleared by a simple, convenient ultrafiltration technique. The filtration removed essentially all of the very-low- and low-density-lipoproteins without removing appreciable amounts of high-density-lipoproteins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of high-density lipoprotein cholesterol in serum: comparison of six isolation methods combined with enzymic cholesterol analysis.

We compared six methods for isolating high-density lipoproteins from normal and lipemic serum. Cholesterol was determined by two different enzymic methods. The values for high-density lipoprotein cholesterol obtained with two (centrifugation-speed) modifications of the heparin/Mn2 method and with the phosphotungstate/Mg2t the dextran sulfate/Mg2, and the polyethylene glycol methods were compare...

متن کامل

Multilaboratory evaluation of an ultrafiltration procedure for high density lipoprotein cholesterol quantification in turbid heparin-manganese supernates.

High density lipoprotein (HDL) can be quantitated by measurement of cholesterol in supernates after precipitation of low and very low density lipoprotein (LDL and VLDL) with heparin and Mn(2+). Supernatant turbidity, often observed with hypertriglyceridemic specimens, indicates incomplete sedimentation of LDL/VLDL and precludes accurate quantitation of HDL. Ten Lipid Research Clinic Laboratorie...

متن کامل

Multi-laboratory comparison of three heparin-Mn2+ precipitation procedures for estimating cholesterol in high-density lipoprotein.

Plasma high-density lipoprotein is commonly estimated by measuring the cholesterol remaining in plasma supernatant solutions after other lipoproteins, which contain apolipoprotein B, are precipitated with heparin and Mn2+. The method (method I) now in use by the Lipid Research Clinics, in which Mn2+ is at 46 mmol/liter final concentration, is reasonably accurate, but precipitation and sedimenta...

متن کامل

High-density-lipoprotein cholesterol in heparin-MnCl2 supernates determined with the Dow enzymic method after precipitation of Mn2+ with HCO3-.

Manganese interferes with enzymic cholesterol methods. In this study, we enzymically measured high-density-lipoprotein (HDL) cholesterol in heparin-Mn2+ supernates that had been treated with NaHCO3 (91 mmol/L) to precipitate Mn2+, and compared results with those by an automated Liebermann- Burchard method. For untreated supernates of 96 fresh plasma samples, the enzymic values were 10.4% higher...

متن کامل

High-density lipoproteins estimated by an enzymatic cholesterol procedure, with a centrifugal analyzer.

We describe an assay for high-density lipoprotein cholesterol, adapted to a centrifugal analyzer, the GEMSAEC System 3, which includes use of an increased Mn2+concentration (91 mmol/liter) [J. Lipid Res. 19, 65 (1978)] and ethylenediaminetetraacetate [Clin. Chem. 22, 98 (1976)]. Modifications to the GEMSAEC system include reducing the mixing burst and preconditioning the sample tip. Accuracy of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 1978