A Set of Collets for Manipulating the Specimen Holder of the Siemens Electron Microscope
نویسنده
چکیده
The modification of the Siemens electron microscope grid-holder suggested by Elbers (1) among its other advantages reduces contamination by reducing the handling of the specimen holder either with the fingers or using paper tissue or other fabrics. By using the set of collets described here such handling is entirely eliminated although the operations involved in changing the specimen may still be made easily. Figs. 1 to 10 on the facing page show the sequence of operations on extracting the holder from the microscope and dismantling for a specimen change. The specimen holder shown is the type which receives 3 mm. diameter grids. Both the collet tools are made from phosphor-bronze and terminate at each end as split collets, except for the threaded portion A (Fig. 11) which is a standard item supplied with the microscope. Use of the threaded tool as described above still allows S 6.5 CM. = FIGURE 11 The top diagram shows in greater detail the construction of operating ends A and B (see text). The bottom diagram similarly shows ends C and D.
منابع مشابه
Controlled environment specimen transfer.
Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmi...
متن کاملAn in situ nanoindentation specimen holder for a high voltage transmission electron microscope.
We describe in detail, the design, construction, and testing of a specimen holder that allows for the nanoindentation of surfaces while viewing in cross-section in a high voltage transmission electron microscope (TEM). This nanoindentation specimen holder, having three-axis position control of a diamond indenter in combination with micromachined specimens, allows for the first time the dynamic ...
متن کاملBenchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement
Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator. Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...
متن کاملBenchmarking of Siemens Linac in Electron Modes: 8-14 MeV Electron Beams
Introduction: Radiation therapy using electron beams is a promising method due to its physical dose distribution. Monte Carlo (MC) code is the best and most accurate technique for forespeaking the distribution of dose in radiation treatment of patients.Materials and Methods: We report an MC simulation of a linac head and depth dose on central axis, along with profile calculations. The purpose o...
متن کاملLocalization of electron virtual SSD in a Siemens-Primus linear accelerator: Comparison of measurements with Monte Carlo simulation
Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Biophysical and Biochemical Cytology
دوره 8 شماره
صفحات -
تاریخ انتشار 1960