A novel perineal shield for low-dose-rate prostate brachytherapy

نویسندگان

  • Joseph P. Weiner
  • David Schwartz
  • Joseph Safdieh
  • Alex Polubarov
  • Tejas Telivala
  • Matthew Worth
  • David Schreiber
چکیده

PURPOSE To study the impact on radiation exposure to staff through the use of an original perineal shield during low-dose-rate prostate brachytherapy. MATERIAL AND METHODS We designed a 1 mm thick stainless steel shield that duplicates and is able to slide directly over a standard commercialized prostate brachytherapy grid. We then analyzed the post-procedure exposure in 15 consecutive patients who underwent Iodine-125 seed placement. Measurements were performed with and without the shield in place at fixed locations relative to the grid template. Endpoints were analyzed using the paired two-sample t-test, with statistical significance defined as a p-value < 0.05. RESULTS The exposure at the midline grid template ranged from 0.144-0.768 mSv/hr without the shield, and 0.038-0.144 mSv/hr with the shield (p < 0.0001). The exposure 10 cm left of the grid template was 0.134-0.576 mSv/hr without the shield, and 0.001-0.012 mSv/hr with the shield (p < 0.0001). The exposure 10 cm right of the grid template was 0.125-0.576 mSv/hr without the shield, and 0.001-0.012 mSv/hr with the shield (p < 0.0001). The median reduction of exposure at the grid was 76% midline, 98.5% left, and 99% right. Similarly, each individual dose rate was recorded at 25 cm from the perineum, both with and without shield. The median reduction of exposure 25 cm from the perineum was 73.7% midline, 77.7% left and 81.6% right (p < 0.0001). CONCLUSIONS Our novel shield took seconds to install and was non-restrictive during the procedure, and provided at least a four-fold reduction in radiation exposure to the brachytherapist.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perineal recurrence of prostate cancer six years after trans-perineal brachytherapy

We report a case of perineal recurrence of prostate cancer 6 years after low-dose-rate (LDR) brachytherapy for localized prostate cancer. The most common approach to treat such perineal masses, including those occurring after prior biopsy or surgery, is local excision. We report the use of stereotactic radiotherapy with volumetric modulated arc therapy (VMAT) as a novel non-invasive, potentiall...

متن کامل

Focal application of low-dose-rate brachytherapy for prostate cancer: a pilot study

PURPOSE To evaluate the feasibility and to report the early outcomes of focal treatment of prostate cancer using low-dose-rate brachytherapy (LDR-PB). MATERIAL AND METHODS Seventeen patients were screened with multi-parametric magnetic resonance imaging (mpMRI), 14 of whom proceeded to receive trans-perineal template mapping biopsy (TTMB). Focal LDR-PB was performed on five eligible patients ...

متن کامل

Determination of Dosimetric Characteristics of IrSeed 125I Brachytherapy Source

Introduction Low dose rate brachytherapy sources have been widely used for interstitial implants in tumor sites, particularly in prostate. Dosimetric characteristics of a new IrSeed 125I brachytherapy source have been determined using the LiF thermoluminescent dosimeter (TLD) chips. Materials and Methods Dose rate constant, radial dose function, and anisotropy function around the IrSeed 125I so...

متن کامل

Determination of dosimetric parameters for shielded 153Gd source in prostate cancer brachytherapy

BACKGROUND Interstitial rotating shield brachytherapy (I-RSBT) is a recently developed method for treatment of prostate cancer. In the present study TG-43 dosimetric parameters of a 153Gd source were obtained for use in I-RSBT. MATERIALS AND METHODS A 153Gd source located inside a needle including a Pt shield and an aluminum window was simulated using MCNPX Monte Carlo code. Dosimetric parame...

متن کامل

Interstitial rotating shield brachytherapy for prostate cancer.

PURPOSE To present a novel needle, catheter, and radiation source system for interstitial rotating shield brachytherapy (I-RSBT) of the prostate. I-RSBT is a promising technique for reducing urethra, rectum, and bladder dose relative to conventional interstitial high-dose-rate brachytherapy (HDR-BT). METHODS A wire-mounted 62 GBq(153)Gd source is proposed with an encapsulated diameter of 0.59...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015