Isotope-ratio-monitoring Liquid Chromatography First Results from a Moving Wire Interface System Mass Spectrometry (irm-lcms): W. A. Brand and P. Dobberstein
نویسندگان
چکیده
A Liquid Chromatography-Combustion (LC-C) Interface, based on a moving wire technique, has been built and tested. The LC effluent is deposited onto a transport wire, which carries the sample through solvent evaporation and combustion ovens. CO, from the combustion step is analysed in an isotope ratio mass spectrometer. Performance of the interface was tested by loop injections of sucrose and glucose into a liquid flow of methanol/water (80/20). Accuracy and precision of 613C,,,< 1% was achieved for sample concentrations > 500 ng/ul (5p1 loop), sufficient for studies at natural isotope ratios. In case of 13C tracer applications the detection limit was determined to be about 20 pg carbon tracer (on wire).
منابع مشابه
High-resolution dO analysis of tooth enamel phosphate by isotope ratio monitoring gas chromatography mass spectrometry and ultraviolet laser fluorination
The viability of oxygen isotope analysis of tooth enamel by UV laser ablation and fluorination has been demonstrated by comparison with the Ag PO extraction method. In-situ analyses by UV laser fluorination using both isotope ratio mass 3 4 Ž . spectrometry and isotope ratio monitoring gas chromatography mass spectrometry irm-GCMS microanalysis are comparaŽ . 18 ble to those of the Ag PO method...
متن کاملHigh precision isotope ratio monitoring techniques in mass spectrometry.
Isotope ratio monitoring following on-line combustion is a new method in gas chromatography/mass spectrometry (GC/MS) that allows the ratios of abundances of stable isotopes of elements such as carbon and nitrogen to be determined for individual compounds introduced via a gas chromatograph. It is the first combustion method that allows direct measurement of isotope ratios of individual molecula...
متن کاملA Quick and Sensitive Liquid Chromatography-Tandem Mass Spectrometry (LC-MS) Method for the Evaluation of Two Formulations of Amlodipine and Atorvastatin in Healthy Male Volunteers
An open-label, single-dose, randomized, 2-way crossover study was conducted in fasted healthy Iranian male volunteers. Eligible participants randomly assigned in a 1:1 ratio to be given one tablet of the test or reference formulation, followed by a 2-week washout period and administration of the exchange formulation. A quick and susceptible Liquid Chromatography–tandem Mass Spectro...
متن کاملData reduction of isotope-resolved LC-MS spectra
MOTIVATION Data reduction of liquid chromatography-mass spectrometry (LC-MS) spectra can be a challenge due to the inherent complexity of biological samples, noise and non-flat baseline. We present a new algorithm, LCMS-2D, for reliable data reduction of LC-MS proteomics data. RESULTS LCMS-2D can reliably reduce LC-MS spectra with multiple scans to a list of elution peaks, and subsequently to...
متن کاملLiquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...
متن کامل