Traditional meter gates for farm delivery flow measurement from an open channel conveyance have traditionally incorporated round canal gates (Armco type) for control. In recent years, some irrigation water agencies (i.e., irrigation districts) have replaced deteriorating round gates with lower-cost rectangular gates that cover round holes. Similar to the situation described in a companion paper, where round gates were examined, there have been no investigations into flow measurement uncertainty using the existing rating tables for these gates. In this study, two commonly used rectangular gate sizes, 0.46 m (18-in.) and 0.61 m (24-in.), were tested under scenarios of various gate openings, upstream heads, and head differences. Coefficient of discharge (Cd ) values were computed based on actual gate open areas. These improved Cd values were used to generate new discharge rating tables for 0.46 m (18-in.) and 0.61 m (24-in.) rectangular meter gates. Limitations for these rectangular gates are discussed. If guidelines presented in this paper and in the companion paper are followed, the average instantaneous flow measurement uncertainty that could be expected is better than ±5%. However, uncertainty is higher (up to approximately 9.5%) at the lower end of the recommended gate openings [0.10 m (4 in.)] for these rectangular gates.
منابع مشابه
Accuracy of Round Meter Gates for On-Farm Deliveries
Recent California legislation requires irrigation water agencies larger than 25,000 acres to measure volumetric water deliveries within specified levels of relative uncertainty. Although the meter gate is one of the most widely used flow measurement devices in California, little investigation has been conducted into the accuracy, limitations, and uncertainties of the rating tables developed ove...
متن کاملCFD SIMULATION OF FLOW OVER CONTRACTED COMPOUND ARCHED RECTANGULAR SHARP CRESTED WEIRS
Measurement of discharge in open channels is one of the main concerns in hydraulic engineering. The structures used for this aim should be accurate, economical and easy to use. Weirs are among the oldest and most convenient hydraulic structures that have been used in both laboratory and field for flow measurement in open channels. Due to limitations of simple sharp crested weirs, recently compo...
متن کاملAutonomous Wireless Heat Energy Meter based on Piezoelectric Energy Harvester for Heat Energy Measurement in Building Complexes
This paper presents a platform for power autonomous wireless energy meter device using piezoelectric energy harvesters. This device can be mainly used for measuring the share of heat energy consumption in a fair manner in building complex with central heat energy system. In the suggested device, the piezoelectric energy harvester is also used as a flow-meter to reduce the power consumption of t...
متن کاملNumerical modeling of three-phase flow through a Venturi meter using the LSSVM algorithm
One of the challenging problems in the Oil & Gas industry is accurate and reliable multiphase flow rate measurement in a three-phase flow. Application of methods with minimized uncertainty is required in the industry. Previous developed correlations for two-phase flow are complex and not capable of three-phase flow. Hence phase behavior identification in different conditions to designing and mo...
متن کاملمطالعه جریان همزمان از زیر یک دریچه کشویی و روی یک سرریز لبه تیز ذوزنقهای
The combined system of gate and weir is used for flow measurement in open channels. But in case the passing water has floating material and sediment it damages their performance and hence error of measurement will increase. In order to solve this problem, weir and gate can be combined and a concentrated hydraulic system known as weir-gate can be developed, thus allowing sediments transportation...