Doppler echocardiographic evaluation of pulmonary artery flow after modified Fontan operation: importance of atrial contraction.

نویسندگان

  • S A Qureshi
  • R Richheimer
  • R McKay
  • R Arnold
چکیده

Doppler echocardiography was used to evaluate blood flow in the pulmonary artery in 14 patients 2 to 42 months (mean (SD) 17 (12) months) after a modified Fontan operation incorporating a direct atriopulmonary anastomosis. Preoperatively six patients had tricuspid atresia, six had a double inlet left ventricle, and two had pulmonary atresia with an intact ventricular septum. The postoperative rhythm was sinus in 11 patients, junctional in one, ventricular pacing in one, and atrioventricular sequential pacing in one. In one patient the Doppler trace was unsatisfactory for analysis. In all patients forward flow in the pulmonary artery had biphasic peaks related to both atrial and ventricular contraction. The mean (SD) peak flow velocity that was synchronous with atrial contraction was 80 (30) cm/s and that synchronous with ventricular contraction was 74 (23) cm/s. The atrial contribution to total pulmonary artery flow, assessed by velocity-time integrals, varied between 22% and 73% (mean (SD) 45 (14)%). In patients with tricuspid atresia the mean (SD) peak flow velocity with atrial contraction was 90 (27) cm/s and that with ventricular contraction was mean (SD) 68 (24) cm/s. In patients with double inlet left ventricle the mean (SD) peak flow velocity was 67 (36) cm/s with atrial contraction and 80 (25) cm/s with ventricular contraction. The atrial contribution to total pulmonary blood flow in patients with tricuspid atresia was significantly higher (53 (11)%) than in those with double inlet left ventricle (37 (14)%). Pulmonary artery flow after modified Fontan operation was biphasic and was related to both atrial and ventricular contraction. The atrial contribution to pulmonary blood flow is greater in patients with tricuspid atresia than in those with a double inlet left ventricle. The mechanism of the second peak related to ventricular contraction is unknown.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler echocardiographic evaluation of pulmonary blood flow after the Fontan operation: the role of the lungs.

OBJECTIVE To document whether the act of respiration influences pulmonary blood flow in patients after the Fontan operation. DESIGN Prospective study in which patients acted as their own controls. SETTING Supraregional paediatric cardiology centre. PATIENTS Sixteen patients who had undergone atriopulmonary anastomosis (Fontan operation) for the treatment of congenital heart disease. INT...

متن کامل

Early diastolic clicks after the Fontan procedure for double inlet left ventricle: anatomical and physiological correlates.

M mode echocardiograms and simultaneous phonocardiograms were recorded in four patients with early diastolic clicks on auscultation. All had double inlet left ventricle and had undergone the Fontan procedure with closure of the right atrioventricular valve orifice by an artificial patch. The phonocardiogram confirmed a high frequency sound occurring 60-90 ms after aortic valve closure and coinc...

متن کامل

THERAPY AND PREVENTION SURGERY Dynamics of right heart flow in patients after Fontan procedure

In seven patients who underwent Fontan procedures but in whom no valves were inserted, dynamics of right heart flow were evaluated with the use of a catheter-tipped velocity transducer, pulsed Doppler echocardiography, and angiocardiography. Right atrial (RA) contraction caused a forward flow to the pulmonary artery (PA) and a backward flow to the inferior vena cava (IVC). Backward flow to the ...

متن کامل

Echocardiographic Assessment of Pulmonary Arteries Pulsatility Index in Fontan Circulation

BACKGROUND Late complications after Fontan procedure may be due to the absence of pump and pulsatile pulmonary blood flow in this type of palliation. Our aim was to quantify the degree of pulsation by echocardiographic method in patients with extracardiac total cavopulmonary connection (ECTCPC) in comparison with biventricular circulation and few cases of pulsatile Fontan. METHODS In a case s...

متن کامل

A different approach to treatment of failing Fontan: Transcatheter covered stent implantation.

A 5-year-old male with a double outlet right ventricle with noncommitted ventricular septal defect and pulmonary stenosis underwent a bidirectional Glenn operation at 2 years and a Fontan operation with ligation of the pulmonary trunk at 5 years. He presented with pleural effusion 3 months after the Fontan operation. Physical examination revealed a grade 3/6 systolic murmur in the pulmonary are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 64 4  شماره 

صفحات  -

تاریخ انتشار 1990