Comparison between semiautomated kinetic perimetry and conventional Goldmann manual kinetic perimetry in advanced visual field loss.
نویسندگان
چکیده
PURPOSE To compare quantitatively visual field (VF) results obtained using a new standardized semiautomated kinetic perimetry (SKP) with those obtained by conventional Goldmann manual kinetic perimetry (MKP) in patients with advanced VF loss. DESIGN Prospective, single-center, observational comparative case series. SUBJECTS AND METHODS Seventy-seven eligible patients (36 suffering from advanced retinal nerve fiber layer loss, 20 with concentric constriction of the VF, and 21 with hemianopia) were included in the study. One eye of each patient was examined on the same day with MKP and SKP. Three isopters, identical in both tests, were chosen to assess the extent of the VF loss. To compare the location and size of the corresponding isopters obtained with MKP and SKP, intersection areas of superimposed isopters were expressed as a percentage of union areas. MAIN OUTCOME MEASURES The area and position of isopters for a defined stimulus condition obtained with both methods were compared. Test duration and patients' preference were also evaluated. RESULTS Isopters obtained with Goldmann MKP enclosed areas smaller by 20% (confidence interval [CI], 12%-27%). The mean intersection area of Goldmann and SKP VFs was 1763.1 square degrees (CI, 1558.6-1967.7) smaller than the union for stimulus III4e over all groups of patients. Semiautomated kinetic perimetry was preferred by 60% of patients with concentric constriction of the VF. Median duration of the examination was 15 minutes and did not differ significantly between the 2 methods. CONCLUSIONS Our results indicate that SKP isopter shape and size were very comparable to those obtained on the same eyes with MKP. Semiautomated kinetic perimetry may represent a more standardized method of kinetic perimetry, which still takes advantage of perimetrist-patient interaction to diagnose and monitor advanced VF loss in clinical practice.
منابع مشابه
A comparison of manual kinetic and automated static perimetry in obtaining ptosis fields.
OBJECTIVE To compare examination time and visual field loss for ptosis fields obtained with manual kinetic (Goldmann) perimetry and automated static (Humphrey) perimetry. METHODS Both eyes of 12 patients with bilateral aponeurogenic ptosis were prospectively examined using Goldmann and Humphrey (ptosis protocol) perimetry with the eyelids ptotic and taped into a normal position. RESULTS Bil...
متن کاملComparison of Diagnostic Accuracy between Octopus 900 and Goldmann Kinetic Visual Fields
PURPOSE To determine diagnostic accuracy of kinetic visual field assessment by Octopus 900 perimetry compared with Goldmann perimetry. METHODS Prospective cross section evaluation of 40 control subjects with full visual fields and 50 patients with known visual field loss. Comparison of test duration and area measurement of isopters for Octopus 3, 5, and 10°/sec stimulus speeds. Comparison of ...
متن کاملA comparison of tangent screen, goldmann, and humphrey perimetry in the detection and localization of occipital lesions.
OBJECTIVE To compare manual kinetic perimetry with tangent screen and Goldmann techniques and automated static perimetry with the Humphrey Field Analyzer in the detection and localization of occipital lobe lesions. DESIGN Prospective consecutive comparative case series. PARTICIPANTS Twelve patients with well-defined occipital lobe infarcts on magnetic resonance (MR) imaging were studied. ...
متن کاملCan Swedish interactive thresholding algorithm fast perimetry be used as an alternative to goldmann perimetry in neuro-ophthalmic practice?
OBJECTIVE To assess the potential role of Swedish Interactive Thresholding Algorithm (SITA) Fast computerized static perimetry, compared with that of Goldmann manual kinetic perimetry (GVF), for reliably detecting visual field defects in neuro-ophthalmic practice. BACKGROUND Automated visual field testing is challenging in patients with poor visual acuity or severe neurological disease. In th...
متن کاملStimulus parameters for goldmann kinetic perimetry in nonorganic visual loss.
OBJECTIVE To investigate the influence of the stimulus parameters on perimetry at various distances and draw conclusions for the clinical exploration of nonorganic visual loss. METHODS Visual field testing using Goldmann kinetic perimetry was performed on 15 healthy volunteers. The I/1e isopter at 33 cm was compared to the I/1e, II/1e and I/2e isopters at 66 cm. The 0/1e isopter at 33 cm was ...