Dual phase 18F-fluorodeoxyglucose positron emission tomography/computed tomography with forced diuresis in diagnostic imaging evaluation of bladder cancer.

نویسندگان

  • N Yildirim-Poyraz
  • E Ozdemir
  • B Uzun
  • S Turkolmez
چکیده

INTRODUCTION (18)F-FDG PET has been regarded as a limited value in urooncology due to urinary excretion of the tracer. The purpose of this retrospective study was to investigate the clinical value of dual-phase FDG PET/CT with forced diuresis protocol (iv furosemide-voiding and oral hydration) in invasive or high grade bladder cancer. METHODS Fifty-one patients were included in this study. All patients underwent standard staging procedures and dual-phase FDG PET/CT before planned therapy. PET/CT findings before and after furosemide were compared with each other for pelvic region. Dual phase PET/CT findings were also compared with the results of prior imaging studies and all findings were correlated with final diagnosis (histopathology or clinical follow-up for at least 12 months). RESULTS Intravesical FDG activity significantly decreased in 90% of the patients with forced diuresis protocol. Eighty eight percent of the bladder findings and 20% of the local lymph node metastases, and other pelvic findings (local invasion and second primary malignancy of prostate) were detected only by the additional pelvic PET/CT images. As a result, dual phase PET/CT changed the staging and/or the therapy strategy in 16 patients (31%). CONCLUSION Dual phase FDG PET/CT contributes staging and decision of therapy strategy by detecting local disease and pelvic metastases with high accuracy when combined with forced diuresis protocol. Thus, we recommend dual phase imaging method with forced diuresis protocol in FDG PET/CT for bladder cancer and all other urogenital system malignities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...

متن کامل

Dual phase F-fluorodeoxyglucose positron emission tomography/computed tomography with forced diuresis in diagnostic imaging evaluation of bladder cancer

Introduction: F-FDG PET has been regarded as a limited value in urooncology due to urinary excretion of the tracer. The purpose of this retrospective study was to investigate the clinical value of dual-phase FDG PET/CT with forced diuresis protocol (iv furosemide-voiding and oral hydration) in invasive or high grade bladder cancer. Methods: Fifty-one patients were included in this study. All pa...

متن کامل

Evaluation of Simultaneous Dual-radioisotope SPECT Imaging Using 18F-fluorodeoxyglucose and 99mTc-tetrofosmin

Objective(s): Use of a positron emission tomography (PET)/single-photonemission computed tomography (SPECT) system facilitates the simultaneousacquisition of images with fluorine-18 fluorodeoxyglucose (18F-FDG) andtechnetium (99mTc)-tetrofosmin. However, 18F has a short half-life, and 511keV Compton-scattered photons are detected in the 99mTc energy window.Therefore, in this study, we aimed to ...

متن کامل

Predictive ability of 18F-fluorodeoxyglucose positron emission tomography/computed tomography for pathological complete response and prognosis after neoadjuvant chemotherapy in triple-negative breast cancer patients

Objective The mortality of patients with locally advanced triple-negative breast cancer (TNBC) is high, and pathological complete response (pCR) to neoadjuvant chemotherapy (NAC) is associated with improved prognosis. This retrospective study was designed and powered to investigate the ability of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) to predict pat...

متن کامل

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de medicina nuclear e imagen molecular

دوره 32 4  شماره 

صفحات  -

تاریخ انتشار 2013