Stability of arterial to end-tidal carbon dioxide gradients during postoperative cardiorespiratory support.
نویسندگان
چکیده
The changes in the arterial to end-tidal carbon dioxide gradient. P(a-ET)CO2, were studied in postoperative cardiac surgery patients from the time of admission to the intensive care unit, during changing cardiorespiratory support, up to the time of tracheal extubation. Individual factors evaluated for their effects on P(a-ET)CO2 included rate of mechanical ventilation, infusion of vasoactive agents (nitroglycerin, nitroprusside, dopamine, dobutamine, and metariminol), and associated changes in haemodynamic pathophysiology (cardiac index, pulmonary artery pressure, pulmonary vascular resistance index, systemic vascular resistance index, and pulmonary capillary wedge pressure). After approval by the Clinical Investigation Committee, 59 patients, age 63 +/- 9 (41 to 75) yr, were studied and 382 individual gradient determinations made. Mean P(a-ET)CO2 was 5.47 +/- 5.21 mmHg, with the mean PaCO2, 36.51 +/- 5.89 mmHg and mean ETCO2, 31.04 +/- 6.44 mmHg. For the population as a whole, the correlation between PaCO2 and ETCO2 determined by regression analysis was maintained (R = 0.644, P less than 0.001). Comparison of the individual and population correlation coefficients by Student's t test showed no significant difference, but a normal population distribution of the gradients (P less than 0.05). None of the variables assessed could be determined to influence P(a-ET)CO2 significantly. For many of the individual patients, however, the relationship between PaCO2 and ETCO2 did not maintain a significant correlation throughout the study period. In the postoperative cardiac surgery patient population P(a-ET)CO2 follows a normal distribution and PaCO2 and ETCO2 maintain a statistically significant correlation. However, when evaluating individual patients, this relationship has wide variability.
منابع مشابه
End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning
Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...
متن کاملInvestigating the Relationship Between End Tidal Carbon Dioxide and Arterial Carbon Dioxide Pressure in Patients With Respiratory Distress Referred to the Emergency Room of Hazrat Rasool Akram Hospital
Background: Measuring End-Tidal Carbon Dioxide (ETCO-2) can be a non-invasive, fast, and reliable method to predict partial pressure of carbon dioxide (PaCO2) in patients with respiratory distress. This method, which can be a suitable substitute to measure PaCO2, is being used in many emergency rooms and operating rooms in developed countries, but its exact relationship with PaCO2 has not been ...
متن کاملتأثیر تهویه با حجمهای جاری متفاوت و تهویه دقیقهای ثابت بر روی دیاکسید کربن انتهای بازدمی
Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2 and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...
متن کاملبررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)
Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...
متن کاملThe Diagnostic Value of End-tidal Carbon Dioxide (EtCO2) and Alveolar Dead Space (AVDS) in Patients with Suspected Pulmonary Thrombo-embolism (PTE)
Introduction: Capnography, is an easy, fast and practical method which its application in the diagnosis of Pulmonary Thromboendarterectomy (PTE) has recently been studied. This study aimed to assess the diagnostic value of end-tidal CO2 (ETCO2) and the alveolar dead space (AVDS) in the diagnosis of patients suspected to PTE who have been referred to the emergency department. Materials and Metho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 37 5 شماره
صفحات -
تاریخ انتشار 1990