The acquisition method for planar 67Ga imaging has hardly changed for 30 years. In this study, in order to improve image quality and diagnostic accuracy, we take steps to optimize the acquisition method, and to choose a scatter correction. First, we acquired individual images from the 93 keV, 185 keV, and 300 keV photopeak; then the images were added together and compared to the individual images. Second, we compared results from a low-medium-energy (LME) collimator with those from a conventional medium-energy (ME) collimator. Also, we examined whether to combine the data from all three of the usual window locations (set about 93 keV, 185 keV, and 300 keV) or to use the data from only two. Third, we compared results from a conventional photopeak ± 10% window with those from a photopeak ± 9 keV window. Fourth, for scatter correction we compared results using the triple energy window (TEW) method with those using the multi-photopeak dual window (MDW) method. The phantoms studied were cold rods in a uniform background, and hot spheres within a cylinder containing uniformly radioactive water. The clinical study involved 22 patients with lung lesions. By the comparison by the contrast ratio in cold rods phantom, 15.6% is improved in LME (2 peaks) than ME (3 peaks), and 3.2% is improved in photopeak ± 9 keV than photopeak ± 10%, 10.2% is improved in TEW than MDW. However, the TEW scatter correction method recognized unstable to the contrast ratio in a clinical study. In addition, a body outline might disappear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between early and delayed images of 67Ga scintigraphy for evaluation of recurrent lymphoma

Introduction: Despite widespread use of 67Gallium for lymphoma evaluation, timing of imaging after injection is a matter of controversy and to the extent of our knowledge no direct comparison has been made between early and delayed gallium images. We aimed to compare 24 and 48 hours post injection planar gallium imaging for evaluation of lymphoma recurrence. Methods: 255 pa...

متن کامل

Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy.

In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67Ga-citrate (67Ga). Image interpretation was performed for the 120 patients ...

متن کامل

Clinical impact of whole body FDG-PET on the staging and therapeutic decision making for malignant lymphoma.

OBJECTIVES The aim of this study is to evaluate the clinical impact of whole-body FDG-PET for the pre-therapeutic evaluation of malignant lymphoma and compared to that of 67Ga-scintigraphy when added to non-RI examinations. METHODS We examined 46 patients with malignant lymphoma including 42 newly diagnosed cases and 4 relapsed cases. Whole-body FDG-PET was started 63 minutes after the admini...

متن کامل

Comparative evaluation of 18F-FDG PET and 67Ga scintigraphy in patients with sarcoidosis.

UNLABELLED 67Ga scintigraphy has been used for years in sarcoidosis for diagnosis and the extent of the disease. However, little information is available on the comparison of 18F-FDG PET and 67Ga scintigraphy in the assessment of sarcoidosis. The purpose of this study was to compare the uptake of 18F-FDG and 67Ga in the evaluation of pulmonary and extrapulmonary involvement in patients with sar...

متن کامل

The ability of 67Ga scintigraphy to detect the lesions of Echinococcus multilocularis infection: preliminary results.

AIM To assess the ability of 67Ga scintigraphy to detect the lesions of Echinococcus multilocularis (EM) infection. MATERIALS AND METHODS An animal model of EM infection was developed. The infected tissues taken from stock infection were placed into the abdominal cavity of uninfected animals operatively. The success of implantation was controlled 20-25 days after implantation. Five infected a...

متن کامل