Comparison of flow-resistive work load due to humidifying devices.

نویسندگان

  • M Nishimura
  • M K Nishijima
  • T Okada
  • N Taenaka
  • I Yoshiya
چکیده

There are many kinds of humidifying devices. We evaluated six humidifiers from the viewpoint of AWLs. The AWL was obtained by calculating the area difference between pressure-volume tracings obtained without and with humidifiers. To examine the effect of pressure monitoring sites on AWL when a humidifier is placed, we measured AWL at three different pressure monitoring sites. The AWL was affected significantly by the pressure monitoring site for the ventilator. When a pressure monitor sensor was placed on the inspiratory limb between the inspiratory valve and humidifiers, the ventilator was not able to compensate for the pressure drop caused by impedance characteristics of the humidifier equipment. This resulted in significant inspiratory AWL on the patient. Thus, humidifying devices should be carefully selected from the viewpoint of not only humidifying capability but also AWL. Furthermore, we must recognize the importance of the pressure monitoring site for the ventilator.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Design of Quaternary Inverter ‎Gate Based on GNRFET

   This paper presents a novel design of quaternary logic gates using graphene nanoribbon field effect transistors (GNRFETs). GNRFETs are the alternative devices for digital circuit design due to their superior carrier-transport properties and potential for large-scale processing. In addition, Multiple-valued logic (MVL) is a promising alternative to the conventional binary logic design. Sa...

متن کامل

Damping of visco-resistive Alfven waves in solar spicules

Interaction of Alfven waves with plasma inhomogeneity generates phase mixing which can cause the dissipation of Alfven waves. We investigated the dissipation of standing Alfven waves due to phase mixing at the presence of steady flow and sheared magnetic field in solar spicules. Moreover, the transition region between chromosphere and corona was considered. Our numerical simulation showed that ...

متن کامل

Analysis and Comparison of Load Flow Methods for Distribution Networks Considering Distributed Generation

Conventional passive distribution networks are changing to modern active distribution networks which are not radial. Conventional load flow methods should be modified for new distribution networks analysis. In modern distribution networks distributed generation (DG) units are embedded with conventional and/or renewable resources. DG units are generally modeled as PV or PQ nodes which inject ...

متن کامل

FACTS Devices Allocation Using a Novel Dedicated Improved PSO for Optimal Operation of Power System

Flexible AC Transmission Systems (FACTS) controllers with its ability to directly control the power flow can offer great opportunities in modern power system, allowing better and safer operation of transmission network. In this paper, in order to find type, size and location of FACTS devices in a power system a Dedicated Improved Particle Swarm Optimization (DIPSO) algorithm is developed for de...

متن کامل

UPFC Siting and Sizing in Power Network Using Two Different Evolutionary Algorithm

In emerging electric power systems, increased transactions often lead to the situations where the system no longer remains in secure operating region. The flexible Ac transmission system (FACTS) controllers can play an important role in the power system security enhancement. However, due to high capital investment, it is necessary to locate these controllers optimally in the power system. FACTS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 97 3  شماره 

صفحات  -

تاریخ انتشار 1990