Effect of different polymerization devices on the degree of conversion and the physical properties of an indirect resin composite.
نویسندگان
چکیده
Polymerization of indirect resin composites (IRC) is carried out in the 'laboratories using special photo-polymerization devices to achieve a higher degree of conversion (DC). Such devices present variation in chambers and light output which may have consequences on the chemical and physical properties of IRCs. This study evaluated the effect of different polymerization devices on the flexural strength, Vickers microhardness and DC of an IRC. Specimens were prepared from an IRC material, Sinfony (3M ESPE), using special molds for flexural strength test (N=30) (25 x 2 x 2 mm, ISO 4049), Vickers microhardness test (N=30) (5 x 4 mm) and for DC (N=30) utilizing Micro-raman Spectroscopy. All specimens were submitted to initial polymerization with a Visio Alpha unit (3M ESPE) and then randomly divided into three groups (n=10/ group). Specimens in Group 1 (control) received additional polymerizations using a Visio Beta Vario device (3M ESPE), and those in Group 2 and Group 3 using Powerlux (EDG) and Strobolux (EDG) devices, respectively. DC and mechanical tests were then conducted. For the mechanical tests, the data were analyzed using ANOVA and Tukey's tests (p < 0.05) and for DC, one-way ANOVA was used. Polymerization in Strobolux (Group 3) resulted in significantly lower flexural strength (MPa) values (134 +/- 27) compared to Visio Beta Vario (165 +/- 20) (Group 1) (p < 0.05). The lowest microhardness values (Kg/mm2) were obtained in Group 3 (30 +/- 1) (p < 0.05). DC was similar in all groups (75 +/- 1, 91 +/- 5, 85 +/- 7% for Visio Beta Vario, Powerlux and Strobolux, respectively) (p = 0.1205). The type of polymerization device may affect the flexural strength and Vickers hardness of the IRC tested. DC also seems to be affected by the type of polymerization device but the results were not significant.
منابع مشابه
The Effect of Standard and Extended Curing Time in Different Distances on Composite’s Degree of Conversion
Introduction: The aim of this study was to in-vestigate the effect of irradiation duration and distance of light tip to prepared samples in two different light curing unites on the degree of conversion of resin composite. Materials and Methods: Conventional halogen and blue Light emitting diode (LED) units were used for polymerization of an Opalis resin com-posite. The conversion measurements w...
متن کاملEffect of Three Light Curing Protocols and Load Cycling on Microleakage of Class V Composite Restorations
Objective: Different methods have been suggested to overcome the polymerization shrinkage of composite restorations. Changing the light curing protocol to improve polymerization by using new light curing units is among these methods. The new devices are more efficient, portable and durable and produce less heat. This study aimed to assess the marginal microleakage of class V composite restora...
متن کاملاثر روش های سخت کنندگی با انواع متفاوت تابش نور بر ریزنشت و درجه تبدیل ترمیم های کامپوزیتی
Statement of Problem: Recently, investigators have presented new methods to reduce polymerization shrinkage of composite resin restorations. It is claimed that more powerful light cure systems associated with a change in radiation patterns, lead to improved mechanical properties and reduced microleakage. Purpose: The aim of the present study was to evaluate the effects of two curing systems, kn...
متن کاملمقایسه استحکام باند سمان رزینی با کامپوزیت غیر مستقیم آماده شده با توانهای لیزر ER YAG و سندبلاست
Background and Aims: Indirect composites are designed to overcome the shortcomings of direct composites such as polymerization shrinkage and low degree of conversion. But, good adhesion of resin cements to indirect composites is still difficult. This research was designed to assess the effect of different powers of ErYAG laser compared with sandblasting. On the micro tensil bond strength of r...
متن کاملEffect of Shade on Immediate and Post-Curing Polymerization Shrinkage of Composite Resin
Background and Aim: Minimizing the polymerization shrinkage of composite resins is a critical goals in composite restorations. Many factors affect polymerization shrinkage. This study aimed to evaluate the effect of composite resin shade on polymerization shrinkage. Materials and Methods: In this in vitro study, 14 composite discs measuring 1.5×8 mm were fabricated. The samples were prepared u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta odontologica latinoamericana : AOL
دوره 23 2 شماره
صفحات -
تاریخ انتشار 2010