Systematic evaluation of 99mTc-tetrofosmin versus 99mTc-sestamibi to study murine myocardial perfusion in small animal SPECT/CT

نویسندگان

  • Alexis Vrachimis
  • Sven Hermann
  • Domokos Máthé
  • Otmar Schober
  • Michael Schäfers
چکیده

BACKGROUND The "back-translation" of clinically available protocols to measure myocardial perfusion to preclinical imaging in mouse models of human disease is attractive for basic biomedical research. With respect to single-photon emission computed tomography (SPECT) approaches, clinical myocardial perfusion imaging protocols are established with different 99mTc-labeled perfusion tracers; however, studies evaluating and optimizing protocols for these tracers in high-resolution pinhole SPECT in mice are lacking. This study aims at evaluating two clinically available 99mTc-labeled myocardial perfusion tracers (99mTc-sestamibi vs. 99mTc-Tetrofosmin) in mice using four different imaging protocols. METHODS Adult C57BL/6 male mice were injected with 99mTc-sestamibi (MIBI) or 99mTc-Tetrofosmin (TETRO) (4 MBq/g body weight) either intravenously through the tail vein (n = 5) or retroorbitally (n = 5) or intraperitoneally (i.p.) under anesthesia (n = 3) or i.p. in an awake state (n = 3) at rest. Immediately after injection, a multi-frame single-photon emission computed tomography/computed tomography (SPECT/CT) acquisition was initiated with six subsequent time frames of 10 min each. Reconstructed images of the different protocols were assessed and compared by visual analysis by experts and by time-activity-curves generated from regions-of-interest for various organs (normalized uptake values). RESULTS Visually assessing overall image quality, the best image quality was found for MIBI for both intravenous injection protocols, whereas TETRO only had comparable image quality after retroorbital injections. These results were confirmed by quantitative analysis where left ventricular (LV) uptake of MIBI after tail vein injections was found significantly higher for all time points accompanied with a significantly slower washout of 16% for MIBI vs. 33% for TETRO (p = 0.009) from 10 to 60 min post injection (PI). Interestingly, LV washout from 10 to 60 min PI was significantly higher for TETRO when applied by tail vein injections when compared to retroorbital injections (22%, p = 0.008). However, liver uptake was significant and comparable for both tracers at all time points. Radioactivity concentration in the lungs was negligible for all time points and both tracers. CONCLUSION Intravenous MIBI injection (both tail vein and retroorbital) results in the best image quality for assessing myocardial perfusion of the murine heart by SPECT/CT. TETRO has a comparable image quality only for the retroorbital injection route.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Filter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]

Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...

متن کامل

99mTc-Tetrofosmin in Rats

99mTc-[bis (dimethoxypropylphosphinoethyl)-ethoxyethylamine (PNP5)]-[bis (N-ethoxyethyl)-dithiocarbamato (DBODC)] nitride (N-PNP5-DBODC or N-DBODC5) is a new monocationic myocardial perfusion tracer. We sought to compare the myocardial uptake and clearance kinetics and organ biodistribution of 99mTc-N-DBODC5 with 99mTc-sestamibi and 99mTc-tetrofosmin. Methods: Seventy-five anesthetized Sprague–...

متن کامل

Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with coronary artery disease.

UNLABELLED This study was designed to compare the tracer kinetics between 99mTc-sestamibi and 99mTc-tetrofosmin in a heterogeneous group of 24 patients admitted for routine perfusion imaging. METHODS Twelve patients were studied with 99mTc-tetrofosmin and 12 with 99mTc-sestamibi. In each group, six patients had a low likelihood for coronary artery disease, and six patients had angiographicall...

متن کامل

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Myocardial uptake characteristics of three 99mTc-labeled tracers for myocardial perfusion imaging one hour after rest injection.

OBJECTIVE 99mTc-tetrofosmin and 99mTc-sestamibi are approved tracers for myocardial perfusion studies. Recently, a 99mTc-MIBI preparation from a different manufacturer (99mTc-cardiospect-MIBI) has been introduced to the market. Therefore, the aim of this study was the evaluation of 99mTc-tetrofosmin as well as of two different 99mTc-labeled MIBI tracers with regard to differences in imaging qua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2012