Increased rate of catheter-related bloodstream infection associated with use of a needleless mechanical valve device at a long-term acute care hospital.

نویسندگان

  • Cassandra D Salgado
  • Libby Chinnes
  • Tammy H Paczesny
  • J Robert Cantey
چکیده

OBJECTIVE To determine whether introduction of a needleless mechanical valve device (NMVD) at a long-term acute care hospital was associated with an increased frequency of catheter-related bloodstream infection (BSI). DESIGN For patients with a central venous catheter in place, the catheter-related BSI rate during the 24-month period before introduction of the NMVD, a period in which a needleless split-septum device (NSSD) was being used (hereafter, the NSSD period), was compared with the catheter-related BSI rate during the 24-month period after introduction of the NMVD (hereafter, the NMVD period). The microbiological characteristics of catheter-related BSIs during each period were also compared. Comparisons and calculations of relative risks (RRs) with 95% confidence intervals (CIs) were performed using chi (2) analysis. RESULTS Eighty-six catheter-related BSIs (3.86 infections per 1,000 catheter-days) occurred during the study period. The rate of catheter-related BSI during the NMVD period was significantly higher than that during the NSSD period (5.95 vs 1.79 infections per 1,000 catheter-days; RR, 3.32 [95% CI, 2.88-3.83]; P<.001). A significantly greater percentage of catheter-related BSIs during the NMVD period were caused by gram-negative organisms, compared with the percentage recorded during the NSSD period (39.5% vs 8%; P=.007). Among catheter-related BSIs due to gram-positive organisms, the percentage caused by enterococci was significantly greater during the NMVD period, compared with the NSSD period (54.8% vs 13.6%; P=.004). The catheter-related BSI rate remained high during the NMVD period despite several educational sessions regarding proper use of the NMVD. CONCLUSIONS An increased catheter-related BSI rate was temporally associated with use of a NMVD at the study hospital, despite several educational sessions regarding proper NMVD use. The current design of the NMVD may be unsafe for use in certain patient populations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Outbreak of bloodstream infection temporally associated with the use of an intravascular needleless valve.

BACKGROUND Needleless intravascular catheter connector valves have been introduced into clinical practice to minimize the risk of needlestick injury. However, infection-control risks associated with these valves may be underappreciated. In March 2005, a dramatic increase in bloodstream infections was noted in multiple patient care units of a hospital in temporal association with the introductio...

متن کامل

Health care-associated bloodstream infections associated with negative- or positive-pressure or displacement mechanical valve needleless connectors.

BACKGROUND Health care-associated, central venous catheter-related bloodstream infections (HA-BSIs) are a major cause of morbidity and mortality. Needleless connectors (NCs) are an important component of the intravenous system. NCs initially were introduced to reduce health care worker needlestick injuries, yet some of these NCs may increase HA-BSI risk. METHODS We compared HA-BSI rates on wa...

متن کامل

Frequency of device-associated infections in intensive care units

Background: Health care associated infections (HAIs) are a class of infections that infect patients during hospital admissions and receive medical services. These infections occurs within 48 to 72 hours of admission and up to 6 weeks after discharge. Surveillance of device-associated infections (DAIs) in intensive care units (ICUs) is substantial in planning healthcare strategies. This study wa...

متن کامل

Bloodstream infection associated with needleless device use and the importance of infection-control practices in the home health care setting.

The influence of infection-control practices on bloodstream infection (BSI) risk was examined in a home health care setting in which three needleless devices were used consecutively. A case-control study and a retrospective cohort study were conducted. Risk factors for BSI included lower education level, younger age, having a central venous catheter (CVC) with multiple ports, or having a tunnel...

متن کامل

Gram-negative bloodstream infections in hematopoietic stem cell transplant patients: the roles of needleless device use, bathing practices, and catheter care.

BACKGROUND Between August 1 and October 30, 1998 (outbreak period), an increased incidence of central venous catheter (CVC)-associated gram-negative bacterial bloodstream infection (GN-BSI) was detected in hematopoietic stem cell transplantation (HSCT) candidates and recipients in an outpatient HSCT unit. The objectives of the present study were to determine strategies for controlling the outbr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2007