Commonly used herbicides, such as sulfentrazone, pose the risk of soil contamination due to their persistence, bioaccumulation and toxicity. Phytoremediation by green manure species has been tested using biomarkers, but analytical data are now required to confirm the extraction of sulfentrazone from soil. Thus, the present work was carried out to analyze sulfentrazone residues in soil based on liquid chromatography with a comparison of these values to the sensitivity of the bioindicator Pennisetum glaucum. The soil samples were obtained after cultivation of Crotalaria juncea and Canavalia ensiformis at four seeding densities and with three doses of sulfentrazone. The seedlings were collected into pots, at two different depths, after 75 days of phytoremediator sowing and then were used to determine the herbicide persistence in the soil. A bioassay with P. glaucum was carried out in the same pot. High-performance liquid chromatography (HPLC), using UV-diode array detection (HPLC/UV-DAD), was used to determine the herbicide residues. The HPLC determination was optimized and validated according to the parameters of precision, accuracy, linearity, limit of detection and quantification, robustness and specificity. The bioindicator P. glaucum was more sensitive to sulfentrazone than residue determination by HPLC. Changes in sulfentrazone concentration caused by green manure phytoremediation were accurately identified by the bioindicator. However, a true correlation between the size of the species and the analyte content was not identified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

High Performance Liquid Chromatographic Determination of Inactive Carboxylic Acid Metabolite of Clopidogrel in Human Serum: Application to a Bioequivalence Study

        A sensitive and rapid method is described for determination of clopidogrel carboxylic acid (CCA), the inactive metabolite of the antiplatelet agent clopidogrel in human serum. The analytical procedure involves liquid-liquid extraction of the analyte and an internal standard (phenytoin) with ethyl acetate. A mobile phase consisting of 0.05 M phosphate buffer containing triethylamine (0.5...

متن کامل

Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS

Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...

متن کامل

Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS

Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecules

دوره 19 8  شماره 

صفحات  -

تاریخ انتشار 2014