Construction of Indistinguishable Conductivity Perturbations for the Point Electrode Model in Electrical Impedance Tomography

نویسندگان

  • Lucas Chesnel
  • Nuutti Hyvönen
  • Stratos Staboulis
چکیده

We explain how to build invisible isotropic conductivity perturbations of the unit conductivity in the framework of the point electrode model for two-dimensional electrical impedance tomography. The theoretical approach, based on solving a fixed point problem, is constructive and allows the implementation of an algorithm for approximating the invisible perturbations. The functionality of the method is demonstrated via numerical examples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Applications of Electrical Impedance Tomography in Neurology

Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...

متن کامل

Electrical impedance tomography

Electrical impedance tomography (EIT) is a noninvasive type of medical imaging in which the electrical conductivity, permittivity, and impedance of a part of the body is inferred from surface electrode measurements and used to form a tomographic image of that part. Electrical conductivity varies considerably among various biological tissues (absolute EIT) or the movement of fluids and gases wit...

متن کامل

Direct calculation of the electrode movement Jacobian for 3D EIT

Electrical Impedance Tomography (EIT) of media with deformable boundaries is very sensitive to electrode movement. This is especially important for EIT images of the thorax, which become distorted with breathing and posture change. Previously, we proposed a reconstruction method for imaging conductivity change and electrode movement based on an indirect perturbation Jacobian calculation, involv...

متن کامل

Detection of multiple inclusions from sweep data of electrical impedance tomography

This paper considers detection of conductivity inhomogeneities inside an otherwise homogeneous object by electrical impedance tomography using only two electrodes: one of the electrodes is held fixed, while the other moves around the examined object. Unit current is maintained between the electrodes, and the corresponding (relative) potential difference is measured as a function of the position...

متن کامل

Modelling of an Oesophageal Electrode for Cardiac Function Tomography

There is a need in critical care units for continuous cardiopulmonary monitoring techniques. ECG gated electrical impedance tomography is able to localize the impedance variations occurring during the cardiac cycle. This method is a safe, inexpensive and potentially fast technique for cardiac output imaging but the spatial resolution is presently low, particularly for central locations such as ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • SIAM Journal of Applied Mathematics

دوره 75  شماره 

صفحات  -

تاریخ انتشار 2015