Comparison of the reflectance method (Reflotron reflectance photometer) with the absorbance method (automatic analysers) for the determination of cholesterol.

نویسندگان

  • G Assmann
  • H Brinkers
  • H Schulte
  • C A Carstensen
چکیده

The European Atherosclerosis Society (1) and the Expert Panel of the US National Cholesterol Education Program (2) have issued detailed guide values for recognition and management of hyperlipidaemia in adults. In these guidelines, the diagnosis of dyslipidaemia based on the measurements of total cholesterol, triacylglycerols, HDL and LDL cholesterol plays an important role. A prerequisite for the desired success of interventive measures is the reliability of the analytical data. The aim of this study was to investigate the precision and accuracy of Reflotron Cholesterol, a method based on the dry chemistry principle. Accuracy was assessed by establishing the correlation with the standardized automated methods used in routine lipid diagnosis. In addition, it was also examined whether the Reflotron Cholesterol results in plasma and blood are comparable. The Reflotron cholesterol (sample: blood) showed a good correlation with the CHOD/PAP method on a Hitachi 737 instrument (sample: plasma). The median value of the differences of the test results was -0.4%. Similarly, the method comparison of Reflotron Cholesterol (sample: blood) versus CHOD/PAP method on a SMAC instrument (sample: plasma) showed that Reflotron produces slightly (1.8%) higher results. The Reflotron Cholesterol values obtained from blood samples were slightly lower than those from plasma samples (median value of the differences: -2.2%). The results suggest that for routine purposes Reflotron Cholesterol provides results which are in good agreement with those obtained by standardized wet chemistry methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Colorimetric determination of potassium in plasma and serum by reflectance photometry with a dry-chemistry reagent.

We evaluated a colorimetric assay of potassium in plasma and serum with the Boehringer Mannheim Reflotron reflectance photometric analyzer, which is designed for near-patient testing in hospitals and physicians' offices. This potassium method does not require calibration or instrument maintenance by the operator. Analysis of 30 microL of plasma or serum takes approximately 140 s. Within-day imp...

متن کامل

Improvement of the Classification of Hyperspectral images by Applying a Novel Method for Estimating Reference Reflectance Spectra

Hyperspectral image containing high spectral information has a large number of narrow spectral bands over a continuous spectral range. This allows the identification and recognition of materials and objects based on the comparison of the spectral reflectance of each of them in different wavelengths. Hence, hyperspectral image in the generation of land cover maps can be very efficient. In the hy...

متن کامل

Accuracy and precision of analyses for total cholesterol as measured with the Reflotron cholesterol method.

We compared plasma cholesterol measurements made with the Boehringer Mannheim Reflotron reflectance photometric analyzer in 1298 capillary blood samples with measurements made in venous blood samples collected at the same time and analyzed in four standardized Lipid Research Clinics laboratories. The Reflotron measurements averaged 0.8% to 7.8% lower than the laboratory values. Correlations (r)...

متن کامل

Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares

The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...

متن کامل

Determination of Leaf Relative Water Content of Two Genotypes of Sesame Using Visible and Near- Infrared (VIS/NIR) Spectrometry to Detect Drought Stress

Relative water content (RWC) in plants is one of the most important biochemical parameters and its deficiency limits efficiency of photosynthesis and crop productivity. The scientific reports on using spectroscopy in detecting drought stress for sesame plants are very rare. In this study, the possibility of identifying water stress in two sensitive (Naz-Takshakhe) and resistant (Yekta) genotype...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical chemistry and clinical biochemistry. Zeitschrift fur klinische Chemie und klinische Biochemie

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 1989