Effect of pulsatile flow perfusion on decellularization
نویسندگان
چکیده
BACKGROUND Decellularized animal organs have been used as scaffolds for tissue engineering. To make a properly functioning scaffolds, the extracellular matrix (ECM) components must be preserved after decellularization. Because pulsatile flow is known to be beneficial for tissue perfusion, pulsatile perfusion of a detergent might decrease the exposure time of the tissues to the detergent used for decellularization. Using Energy Equivalent Pressure (EEP) as a pulsatility parameter, the effect of pulsatile flow in decellularization process is studied. RESULTS Twelve rat hearts were decellularization with 1% sodium dodecyl sulfate (SDS) solution for 2 h. They are divided into two groups, one with pulsatile perfusion (n = 6), the other with non-pulsatile perfusion (n = 6) of SDS. The initial mean perfusion pressures were same in both group. The result indicated that the EEP and the perfusion flow were increased significantly in the pulsatile group compared to the non-pulsatile group. Photographs taken during the decellularization showed more profound decellularization in the pulsatile group. The residual DNA content in the scaffolds was significantly lower in the pulsatile group. However, the level of ECM components, collagen and GAG showed no significant differences between the groups. CONCLUSIONS Decellularization is more efficient in pulsatile flow than in non-pulsatile flow but still preserves the ECM molecules.
منابع مشابه
Utilization of Pulsatile flow to Decellularize the Human Umbilical Arteries to Make Small-Caliber Blood Vessel Scaffolds.
PURPOSE To explore the effect of pulsatile flow in the decellularization process of small blood vessels. METHODS A total of 30 human umbilical cords were used in the current study. The umbilical cords were flushed with 0.25% trypsin/0.01% EDTA for 30 minutes, followed by treatment with 1% sodium dodecyl sulfate sodium dodecyl sulfate for 3 hours. The effectiveness of decellularization on the ...
متن کاملAn implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery
With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...
متن کاملEffect of six non-Newtonian viscosity models on hemodynamic parameters of pulsatile blood flow in stenosed artery
A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with A numerical study of hemodynamic parameters of pulsatile blood flow is presented in a stenotic artery with non-Newtonian models using ADINA. Blood flow was considered laminar, and the arterial wall was considered rigid. Studied stenosis severities were 30, 50, and 70% of the cross-section...
متن کاملPeripheral vascular resistance and angiotensin II levels during pulsatile and non-pulsatile cardiopulmonary bypass.
The effects of pulsatile and non-pulsatile cardiopulmonary bypass (CPB) on levels of peripheral vascular resistance and plasma angiotensin II (AII) have been studied in 24 patients submitted to elective cardiac surgical procedures. Twelve patients had conventional non-pulsatile perfusion throughout the period of CPB (non-pulsatile group), while 12 had pulsatile perfusion during the central peri...
متن کاملThe effect of pulsatile cardiopulmonary bypass on lung function in elderly patients.
PURPOSE Cardiopulmonary bypass is still a major cause of lung injury and delay in pulmonary recovery after cardiac surgery. Although it has been shown that pulsatile flow induced by intra-aortic balloon pumping is beneficial for preserving lung function, it is not clear if the same beneficial effect can be accomplished with pulsatile flow generated in the extracorporeal circuit. Therefore, we i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2018