Impact of introducer sheath coating on endothelial function in humans after transradial coronary procedures.
نویسندگان
چکیده
BACKGROUND The aim of this study was to compare the impact of transradial catheterization with hydrophilic-coated catheter sheaths versus uncoated sheaths on NO-mediated endothelial-dependent and -independent vasodilator function. METHODS AND RESULTS Thirty-five subjects undergoing transradial catheterization were recruited and assessed before and the day after catheterization. A subgroup was also assessed 3 to 4 months after catheterization. Subjects received hydrophilic-coated sheaths (n=15) or uncoated sheaths (n=20). Radial artery flow-mediated dilatation and endothelium- and NO-dependent arterial dilatation were assessed within the region of sheath placement. Glyceryl trinitrate endothelium-independent NO-mediated function was also assessed. The noncatheterized arm provided an internal control. Flow-mediated dilatation in the catheterized arm decreased from 10.3+/-3.8% to 5.3+/-3.3% and 8.1+/-2.4% to 5.2+/-3.7% in the coated and uncoated groups, respectively (P<0.01). These values returned toward baseline levels approximately 3 months later (coated, 6.4+/-1.4%; uncoated, 9.4+/-4.1%; P<0.05) versus postprocedure. Glyceryl trinitrate decreased from 14.8+/-7.2% to 9.5+/-4.1% (P<0.05) in the coated group and from 12.2+/-4.6% to 7.5+/-4.2% (P<0.01) in the uncoated group. Values returned to baseline at approximately 3 months (coated, 16.6+/-5.6%; uncoated, 12.1+/-3.9%; P<0.05). There was no difference in the magnitude of decrease in flow-mediated dilatation or glyceryl trinitrate between coated and uncoated groups. No changes in function occurred in the noncatheterized arm. CONCLUSIONS Placement of a catheter sheath inside the radial artery disrupts vasodilator function, which recovers after 3 months. No differences were evident between hydrophilic-coated and uncoated sheaths.
منابع مشابه
Safety and feasibility of the new 5 Fr Glidesheath Slender.
The aim of this study was to evaluate the safety and feasibility of the new 5 Fr Glidesheath Slender (GSS). The transradial (TR) approach has become popular because of several advantages, such as a reduced rate of vascular access site complications. However, because the radial artery is narrow, a limitation of TR access is the potential for artery spasm or occlusion. Studies of radial artery si...
متن کاملFeasibility of Transradial Coronary Intervention Using a Sheathless Guiding Catheter in Patients With Small Radial Artery
BACKGROUND AND OBJECTIVES Transradial coronary angiography and intervention are increasing in frequency due to lower major vascular access site complications and the potential for early mobilization. However, the small size of the radial artery (RA) is a major limitation of this technique. A sheathless guiding catheter (GC) has recently been introduced that has a 1-2 French smaller diameter com...
متن کاملImpact of Catheter Sheath Insertion into the Radial Artery on Vascular Endothelial Function Assessed by Reactive Hyperemia Peripheral Arterial Tonometry.
The transradial approach has been used for coronary procedures, but this procedure carries a risk of injury to the endothelium of the radial artery. In this study, the vascular dysfunction caused by transradial catheterization was examined using reactive hyperemia peripheral arterial tonometry (RH-PAT), a recently developed technique for assessing endothelial function in digits, and the differe...
متن کاملTransradial catheterization can lead to safer , less costly , and more satisfactory coronary angiography and interventions
I mproving safety and reducing cost are the two biggest focuses in health care. In the cath lab, the transradial approach lends itself to achieving both of these objectives by reducing complications related to coronary angiography and intervention, while at the same time reducing hospital stay and increasing throughput. The nuances of performing coronary angiography and interventions through ra...
متن کاملImpact of catheter insertion using the radial approach on vasodilatation in humans.
The aim of this study was to determine the impact of catheter sheath insertion, a model of endothelium disruption in humans, on the conventional FMD (flow-mediated dilatation) response in vivo. Seventeen subjects undergoing transradial catheterization were recruited and assessed prior to, the day after, and 3-4 months postcatheterization. The catheter sheath's external diameter was 2.7 mm, and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 3 2 شماره