Stresses in the ankle joint and total ankle replacement design.

نویسندگان

  • Rahul Kakkar
  • M S Siddique
چکیده

The ankle is a highly congruent joint with a surface area of 11-13 cm(2). Total ankle replacements have been attempted since the early 1970s and design has continually evolved as the early designs were a failure. This was because the stresses involved and the mutiaxial motion of the ankle has not been understood until recently. It has been shown that the talus slides as well as rolls during the ankle arc of motion from plantarflexion to dorsiflexion. Furthermore, the articular surfaces and the calcaneofibular and tibiocalcaneal ligaments have been shown to form a four bar linkage dictating ankle motion. A new design ankle replacement has been suggested recently which allows multiaxial motion at the ankle while maintaining congruency throughout the arc of motion. The early results of this ankle replacement have been encouraging without any reported failures due to mechanical loosening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Total ankle replacement. Design evolution and results.

The ankle joint has unique anatomical, biomechanical and cartilaginous structural characteristics that allow the joint to withstand the very high mechanical stresses and strains over years. Any minor changes to any of these features predispose the joint to osteoarthritis. Total ankle replacement (TAR) is evolving as an alternative to ankle arthrodesis for the treatment of end-stage ankle osteoa...

متن کامل

Joint Distraction in Advanced Osteoarthritis of the Ankle

replacement (TAR) in patients with advanced ankle osteoarthritis (OA). AJD could a tenable option to ankle fusion orTAR.Methods: A review has been performed on the role of AJD in advanced OA of the ankle. The exploration machinewas MedLine. The keywords utilized were: joint distraction ankle. Three hundred and eleven articles were found. Ofthe above-mentioned, only 14 were chosen and analyzed b...

متن کامل

Contact stresses, pressure and area in a fixed-bearing total ankle replacement: a finite element analysis

BACKGROUND Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polye...

متن کامل

Misalignment of total ankle components can induce high joint contact pressures.

BACKGROUND A major cause of the limited longevity of total ankle replacements is premature polyethylene component wear, which can be induced by high joint contact pressures. We implemented a computational model to parametrically explore the hypothesis that intercomponent positioning deviating from the manufacturer's recommendations can result in pressure distributions that may predispose to wea...

متن کامل

Design and Evaluation of an Articulated Ankle Foot Orthosis with Plantarflexion Resistance on the Gait: a Case Series of 2 Patients with Hemiplegia

Ankle-foot orthoses (AFOs) have been described to have positive effects on the gait biomechanics in stroke patients. The plantarflexion resistance of an AFO is considered important for hemiplegic patients, but the evidence is still limited. The purpose of this case series was to design and evaluate the immediate effect of an articulated AFO on kinematics and kinetics of lower-limb joints in str...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2011