Comparison of the Feasibility and Safety of First- versus Second-Generation AMPLATZER™ Occluders for Left Atrial Appendage Closure
نویسندگان
چکیده
INTRODUCTION Left atrial appendage closure (LAAC) is considered an alternative to oral anticoagulation therapy in patients with atrial fibrillation (AF). The aim of this study was to compare the safety and efficacy of the first- and second-generation AMPLATZER Devices for LAAC, AMPLATZER Cardiac Plug (ACP) versus AMPLATZER Amulet™. METHODS Procedural data, such as fluoroscopy time, radiation dose, and contrast-dye, as well as VARC criteria and major adverse events (MAEs) were assessed for both devices. The rate of peridevice leaks was analyzed at echocardiographic follow-up. RESULTS A total of 196 patients with AF underwent LAAC with the ACP (n = 99) or Amulet device (n = 97). The use of Amulet was associated with significantly lower fluoroscopy time (14.8 ± 7.4 min versus 10.6 ± 4.1 min; p < 0.001), lower radiation dose (4833 ± 3360 cGy⁎cm2 versus 3206 ± 2169 cGy⁎cm2; p < 0.001), and reduced amount of contrast-dye (150.2 ± 83.9 ml versus 128.8 ± 46.0 ml; p = 0.03). Furthermore, LAAC with Amulet devices resulted in lower device-resizing rates (3 versus 16 cases; p = 0.001). Peridevice leaks were less frequent in the Amulet group (12 versus 4; p = 0.03). MAE occurred in 6 ACP and 4 Amulet patients (p = 0.58). CONCLUSIONS The Amulet device is associated with shorter fluoroscopy times and radiation dosages, reduced use of contrast-dye, lower recapture rates, and less peridevice leaks as compared to the ACP.
منابع مشابه
Percutaneous closure of the left atrial appendage using the Amplatzer Cardiac Plug in patients with atrial fibrillation: evaluation of safety and feasibility.
BACKGROUND Ischaemic stroke is a common complication of atrial fibrillation (AF). Cardiology societies recommend assessing the risk of ischaemic stroke and using adequate prevention in patients with AF. Currently, oral anticoagulants and antiplatelet drugs are the most commonly used methods of stroke prevention. Left atrial appendage (LAA) is thought to be the main source of thrombi in patients...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملLeft Atrial Appendage Closure with Amplatzer Cardiac Plug in Nonvalvular Atrial Fibrillation: Safety and Long-Term Outcome
BACKGROUND Atrial fibrillation (AF) is a cardiac arrhythmia with high risk for thromboembolic events, specially stroke. OBJECTIVE To assess the safety of left atrial appendage closure (LAAC) with the Amplatzer Cardiac Plug for the prevention of thromboembolic events in patients with nonvalvular AF. METHODS This study included 15 patients with nonvalvular AF referred for LAAC, 6 older than 7...
متن کاملCardiac Plug I and Amulet Devices: Left Atrial Appendage Closure for Stroke Prophylaxis in Atrial Fibrillation.
Percutaneous left atrial appendage (LAA) occlusion has emerged as an exciting and effective modality for stroke prophylaxis in patients with non-valvular atrial fibrillation who are deemed too high risk for anticoagulation with warfarin or newer anticoagulants. The Amplatzer devices have been used in LAA occlusion for more than a decade, starting with off label use of an atrial septal occluder ...