Evaluation of the SVOne Handheld Autorefractor in a Pediatric Population.

نویسندگان

  • Mark Rosenfield
  • Kenneth J Ciuffreda
چکیده

PURPOSE The SVOne is a portable, Hartmann-Shack wavefront aberrometer, which can be attached to a smartphone to determine the refractive error of the eye objectively. Previous results have shown the device to provide measurements equivalent to those of standard clinical techniques in young, healthy adults. The aim of the present study was to compare the findings of the SVOne with retinoscopy, subjective refraction, and two commercially available autorefractors (Retinomax-3 and WAM-5500) in a pediatric population. METHOD The refractive error of the right eye was assessed both without and with cycloplegia in 40 visually normal children between 5 and 17 years of age (mean age = 11.3 years) using the five techniques described above. Further, to assess repeatability of the instruments, the entire procedure was repeated in a subgroup of five subjects. All data were analyzed in terms of power vectors (M, J0, and J45). RESULTS No significant difference was observed between the mean values of M (spherical equivalent) for the different techniques. Retinoscopy showed the best agreement with subjective refraction, both without and with cycloplegia, followed by the open-field WAM-5500. The most repeatable procedures, when measured without and with cycloplegia, were the WAM-5500 and retinoscopy, respectively. Measurements with the SVOne showed a decline in repeatability under cycloplegia. CONCLUSIONS The results indicate that the SVOne provides measurements of refractive error in a normal, pediatric population that are not significantly different from other subjective and objective procedures. Accurate alignment along the visual axis, especially when measuring through a dilated pupil, is critical. This instrument is valuable for vision screenings, for examinations taking place outside the clinical office, and a starting point for the refractive assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the SVOne: A Handheld, Smartphone-Based Autorefractor

PURPOSE The SVOne is a portable Hartmann-Shack wavefront aberrometer that can be attached to a smartphone to determine the refractive error of the eye objectively. The aim of the present study was to compare the findings of the SVOne with retinoscopy, subjective refraction, and two commercially available autorefractors (Topcon KR-1W and Righton Retinomax-3). METHODS Refractive error was asses...

متن کامل

Clinical evaluation of refraction using a handheld wavefront autorefractor in young and adult patients.

PURPOSE To determine the accuracy of measurement by the SureSight autorefractor (software version 2.0) and the influence of accommodation. SETTING Pediatric Section, Department of Ophthalmology, University of Hamburg, Hamburg, Germany. METHODS In a series of comparative measurements, autorefractor readings were compared with cycloplegic retinoscopy in 195 eyes of 108 patients (1 to 81 years...

متن کامل

Design and Clinical Evaluation of a Handheld Wavefront Autorefractor.

PURPOSE To introduce a novel autorefractor design that is intended to be manufacturable at low cost and evaluate its performance in measuring refractive errors. METHODS We developed a handheld, open-view autorefractor (the "QuickSee" [QS]) that uses a simplified approach to wavefront sensing that forgoes moving parts and expensive components. Adult subjects (n = 41) were recruited to undergo ...

متن کامل

Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one...

متن کامل

The use of handheld spectral domain optical coherence tomography in pediatric ophthalmology practice: Our experience of 975 infants and children.

PURPOSE Optical coherence tomography (OCT) is an important imaging tool assessing retinal architecture. In this article, we report a single centers experience of using handheld spectral domain (SD)-OCT in a pediatric population using the Envisu 2300 (Bioptigen Inc., Research Triangle Park, NC, USA). METHODS We studied SD-OCT images from 975 patients imaged from January 2011 to December 2014. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optometry and vision science : official publication of the American Academy of Optometry

دوره 94 2  شماره 

صفحات  -

تاریخ انتشار 2017