Measuring concentrations of ammonia in ambient air or exhaust air stream using acid traps.

نویسندگان

  • P M Ndegwa
  • V K Vaddella
  • A N Hristov
  • H S Joo
چکیده

Strong acid solutions have been widely used in acid traps to determine concentrations of ammonia in ambient air or exhaust air stream. A literature survey indicates the method has a long history and a wide variation in use. Through a series of studies, this paper examines several factors including volume of the acid, depth of the acid, and airflow rate; that might affect the efficiency of sulfuric acid traps and recommends steps researchers and other users may take to ensure reliable results from this method. The results from these series of studies indicate: (i) an inverse relationship between the efficiency of the acid traps and the amount of ammonia to be trapped even when the capacity of the acid trap is excessively greater than the maximum theoretical stoichiometric capacity needed to dissolve all of the ammonia, (ii) for the same volume of acid, the efficiency of the acid trap increased with the acid depth but overall, the efficiency at any given acid depth decreased as the amount of ammonia through the trap increased, and (iii) at the two airflow rates examined in this study (0.5 and 1.0 L/min) the efficiency of the acid traps decreased at similar rates as the concentration of ammonia in the sample air increased but the efficiency of the trap was significantly higher at the lower airflow rate. To obtain reliable measurements from this method, therefore, multi-point calibrations within the entire range of target measurements is recommended to provide accurate corrections of the measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removal of air ammonia in a spray tower by dilute sulfuric acid solution

Introduction: Workplace air quality is a very important factor in community health and is measured by measuring and evaluating airborne contaminants. One of these airborne pollutants is ammonia gas. Spray towers are important components of air pollution control. The aim of this study was to investigate the effects of using diluted sulfuric acid solution on the efficiency of ammonia removal in a...

متن کامل

Air Quality and Emission Measurement Methodology

Reliable measurements of air quality and emissions at large livestock buildings with inherently large spatial and temporal variations of pollutant concentrations are relatively difficult and expensive. Appropriate methodologies for such measurements are not readily apparent and techniques and strategies vary widely. Several important technical issues need to be addressed by an air pollutant emi...

متن کامل

Laboratory-scale investigation of UV treatment of ammonia for livestock and poultry barn exhaust applications.

The feasibility of using deep ultraviolet (UV) treatment for abatement of ammonia (NH(3)) in livestock and poultry barn exhaust air was examined in a series of laboratory-scale experiments. These experiments simulated moving exhaust air through an irradiation chamber with variables of UV wavelength and dose, NH(3) concentrations, humidity, and presence of hydrogen sulfide (H(2)S). Ammonia, init...

متن کامل

Quality-assured measurements of animal building emissions: particulate matter concentrations.

Federally funded, multistate field studies were initiated in 2002 to measure emissions of particulate matter (PM) < 10 microm (PM10) and total suspended particulate (TSP), ammonia, hydrogen sulfide, carbon dioxide, methane, nonmethane hydrocarbons, and odor from swine and poultry production buildings in the United States. This paper describes the use of a continuous PM analyzer based on the tap...

متن کامل

بررسی ارتباط بین غلظت تتراکلرواتیلن در هوای بازدم و سطوح مواجهه فردی در شاغلین خشکشویی

Background: When workplace air monitoring is not sufficient to determine the exposure levels, the determination of compounds and some metabolites in exhaled air and personal exposure levels is considered a practical method for biological monitoring. The aim of this study was to determine the relationship between the concentration of tetrachlorethylene in exhaled air and personal exposure levels...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of environmental quality

دوره 38 2  شماره 

صفحات  -