Percutaneous trephine biopsy of the lung.

نویسنده

  • T A Neff
چکیده

Needle lung biopsy performed with a trephine cutting needle attached to a high speed pneumatic drill is a new technique which can be expected to yield a high quality lung specimen in 85 percent 90 percent of attempts. This technique is especially applicable to diffuse pulmonary disease. The most frequent complication is the development of pneumothorax (in up to 65 percent of biopsies) which if handled appropriately is not dangerous and, therefore, should not be considered to outweigh the benefits of a pathologic and often etiologic diagnosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Spine Biopsy: A Literature Review

Percutaneous spine biopsy has widely replaced open biopsy during the last 50 years. Closed biopsy is more cost effective, less invasive, and has fewer complications than open procedures. A literature search was conducted in PubMed for percutaneous spine biopsy. The contributing factors to the success of the biopsy were identified by reviewing the articles and their references. These factors inc...

متن کامل

Fatal Complication in Percutaneous Needle Biopsy of the Lung

The danger of percutaneous needle biopsy of the lung has been emphasized by the recent report of two additional fatal cases.' The authors review the published fatalities in the English literature, pointing out that they have occurred, except in one case,2 after the use of cutting needles. We have published our own results3 in 18 patients submitted to biopsy with the high speed trephine presente...

متن کامل

Letter: Fatal complication in percutaneous needle biopsy of the lung.

The danger of percutaneous needle biopsy of the lung has been emphasized by the recent report of two additional fatal cases.' The authors review the published fatalities in the English literature, pointing out that they have occurred, except in one case,2 after the use of cutting needles. We have published our own results3 in 18 patients submitted to biopsy with the high speed trephine presente...